HCV RNA Testing of Plasma Samples from Cornea Donors: Suitability of Plasma Samples Stored at 4 °C for up to 8 Days.
Transfusion Medicine and Hemotherapy 2017 January
BACKGROUND: The HCV RNA testing of potential cornea donors frequently relies on blood samples stored pre mortem. The recommended storage time of maximum 72 h frequently excludes a significant fraction of donors.
METHODS: The influence of storage time of EDTA plasma samples at 4 °C on the viral load measured with the Roche HCV Quantitative Test vs. 2.0 was evaluated for 43 samples from HCV-positive individuals.
RESULTS: The mean reduction of the viral load after 4 °C storage for 6-8 days was 0.46 log10 IU/ml (range +0.17 to -1.66 log10 IU/ml). After 1-3 days a mean loss of 0.19 log10 IU/ml (range +0.30 to -1.41 log10 IU/ml) and after 3-5 days of 0.32 log10 IU/ml (range +0.36 to -1.81 log10 IU/ml) was observed. In 23.3% of samples, a viral load reduction ≥ 1 log10 IU/ml (1.0-1.81 log10 IU/ml) was found after prolonged storage (5-8 days). In none of the samples did the HCV load fall below the detection limit.
CONCLUSION: Plasma storage for up to 8 days can quantitatively reduce the HCV RNA load, yet has no influence on the reliability of a qualitative HCV RNA detection by this ultrasensitive test to determine the HCV status of serologically negative cornea donors.
METHODS: The influence of storage time of EDTA plasma samples at 4 °C on the viral load measured with the Roche HCV Quantitative Test vs. 2.0 was evaluated for 43 samples from HCV-positive individuals.
RESULTS: The mean reduction of the viral load after 4 °C storage for 6-8 days was 0.46 log10 IU/ml (range +0.17 to -1.66 log10 IU/ml). After 1-3 days a mean loss of 0.19 log10 IU/ml (range +0.30 to -1.41 log10 IU/ml) and after 3-5 days of 0.32 log10 IU/ml (range +0.36 to -1.81 log10 IU/ml) was observed. In 23.3% of samples, a viral load reduction ≥ 1 log10 IU/ml (1.0-1.81 log10 IU/ml) was found after prolonged storage (5-8 days). In none of the samples did the HCV load fall below the detection limit.
CONCLUSION: Plasma storage for up to 8 days can quantitatively reduce the HCV RNA load, yet has no influence on the reliability of a qualitative HCV RNA detection by this ultrasensitive test to determine the HCV status of serologically negative cornea donors.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app