We have located links that may give you full text access.
Using direct antiglobulin test results to reduce unnecessary cold agglutinin testing.
Transfusion 2017 June
BACKGROUND: Cold agglutinin disease (CAD) is a rare autoimmune hemolytic anemia mediated by autoantibodies that preferentially react at 4°C. Laboratory testing for cold-reactive autoantibodies is laborious and may not be ordered judiciously, particularly in patients with a negative direct antiglobulin test (DAT). We sought to determine whether a negative DAT using anti-human complement (anti-C3) rules out elevated cold agglutinin (CA) titers and the diagnosis of CAD.
STUDY DESIGN AND METHODS: We performed a retrospective study of patients with a CA test performed at three major academic medical centers: Barnes-Jewish Hospital (2003-2014), Vanderbilt University Medical Center (2007-2009), and Massachusetts General Hospital (2009-2014).
RESULTS: This study included 801 patients, of whom 51% (n = 410) had a DAT within the 7 days before CA testing. A total of 98% of patients with a negative DAT using anti-C3 had a negative CA titer (<64). Only five subjects had a negative DAT using anti-C3 and an elevated CA titer.
CONCLUSIONS: Overutilization of CA testing could be reduced by establishing laboratory acceptance criteria based on a positive DAT using anti-C3. Such acceptance criteria would have reduced CA testing by 68% for those with an available DAT result.
STUDY DESIGN AND METHODS: We performed a retrospective study of patients with a CA test performed at three major academic medical centers: Barnes-Jewish Hospital (2003-2014), Vanderbilt University Medical Center (2007-2009), and Massachusetts General Hospital (2009-2014).
RESULTS: This study included 801 patients, of whom 51% (n = 410) had a DAT within the 7 days before CA testing. A total of 98% of patients with a negative DAT using anti-C3 had a negative CA titer (<64). Only five subjects had a negative DAT using anti-C3 and an elevated CA titer.
CONCLUSIONS: Overutilization of CA testing could be reduced by establishing laboratory acceptance criteria based on a positive DAT using anti-C3. Such acceptance criteria would have reduced CA testing by 68% for those with an available DAT result.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app