Incidence of central venous catheter hub contamination.
Journal of Critical Care 2017 June
PURPOSE: To investigate microorganisms causing central venous catheter contamination and how this contamination differs across different catheter metrics.
MATERIALS AND METHODS: After obtaining IRB approval and informed consent, 830 cultures were prospectively obtained from 45 ICU patients with central venous catheter or peripherally inserted central catheter. Bacterial colonies were identified by mass spectrometry.
RESULTS: Bacterial contamination of central catheter hubs occurred 44% of the time in this study in the ICU setting. Coagulase-positive staphylococci cultures had higher median (±interquartile range) CFUs (12±232) versus coagulase-negative (3±10) and other bacteria (1±3; P<0.001). Bacterial contamination was associated with various metrics. Higher incidence (P<0.05) of coagulase-positive staphylococci cultures was associated with hub-only connections (a "hub" being a female connection; 10.9% vs. 7.9% male connections), connections without a manifold (1lumen device that mixes multiple infusions together; 9.7% vs. 0% with manifold); and central venous pressure monitoring connections (25.8% vs. 7.1% without). Internal jugular sites (10.0% vs. 2.7% femoral, 6.2% PICC, P=0.031) and medial lumens of triple lumen catheters (11.9% vs. 5.6% distal, 7.0% proximal, P=0.049) had increased incidence of higher bacteria loads (>15 CFUs).
CONCLUSIONS: This study found a high incidence of central access catheter hub bacterial contamination, which correlated with positive blood cultures in 2 of 3 total bacteremia cases identified in the 45 patients.
MATERIALS AND METHODS: After obtaining IRB approval and informed consent, 830 cultures were prospectively obtained from 45 ICU patients with central venous catheter or peripherally inserted central catheter. Bacterial colonies were identified by mass spectrometry.
RESULTS: Bacterial contamination of central catheter hubs occurred 44% of the time in this study in the ICU setting. Coagulase-positive staphylococci cultures had higher median (±interquartile range) CFUs (12±232) versus coagulase-negative (3±10) and other bacteria (1±3; P<0.001). Bacterial contamination was associated with various metrics. Higher incidence (P<0.05) of coagulase-positive staphylococci cultures was associated with hub-only connections (a "hub" being a female connection; 10.9% vs. 7.9% male connections), connections without a manifold (1lumen device that mixes multiple infusions together; 9.7% vs. 0% with manifold); and central venous pressure monitoring connections (25.8% vs. 7.1% without). Internal jugular sites (10.0% vs. 2.7% femoral, 6.2% PICC, P=0.031) and medial lumens of triple lumen catheters (11.9% vs. 5.6% distal, 7.0% proximal, P=0.049) had increased incidence of higher bacteria loads (>15 CFUs).
CONCLUSIONS: This study found a high incidence of central access catheter hub bacterial contamination, which correlated with positive blood cultures in 2 of 3 total bacteremia cases identified in the 45 patients.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app