Add like
Add dislike
Add to saved papers

Radiofrequency exposure near an attocell as part of an ultra-high density access network.

In the future, wireless radiofrequency (RF) telecommunications networks will provide users with gigabit-per-second data rates. Therefore, these networks are evolving toward hybrid networks, which will include commonly used macro- and microcells in combination with local ultra-high density access networks consisting of so-called attocells. The use of attocells requires a proper compliance assessment of exposure to RF electromagnetic radiation. This paper presents, for the first time, such a compliance assessment of an attocell operating at 3.5 GHz with an input power of 1 mW, based on both root-mean-squared electric field strength (Erms ) and peak 10 g-averaged specific absorption rate (SAR10g ) values. The Erms values near the attocell were determined using finite-difference time-domain (FDTD) simulations and measurements by a tri-axial probe. They were compared to the International Commission on Non-Ionizing Radiation Protection's (ICNIRP) reference levels. All measured and simulated Erms values above the attocell were below 5.9 V/m and lower than reference levels. The SAR10g values were measured in a homogeneous phantom, which resulted in an SAR10g of 9.7 mW/kg, and used FDTD simulations, which resulted in an SAR10g of 7.2 mW/kg. FDTD simulations of realistic exposure situations were executed using a heterogeneous phantom, which yielded SAR10g values lower than 2.8 mW/kg. The studied dosimetric quantities were in compliance with ICNIRP guidelines when the attocell was fed an input power <1 mW. The deployment of attocells is thus a feasible solution for providing broadband data transmission without drastically increasing personal RF exposure. Bioelectromagnetics. 38:295-306, 2017. © 2017 Wiley Periodicals, Inc.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app