Add like
Add dislike
Add to saved papers

Assessment of distribution of ventilation and regional lung compliance by electrical impedance tomography in anaesthetized horses undergoing alveolar recruitment manoeuvres.

OBJECTIVE: To examine changes in the distribution of ventilation and regional lung compliances in anaesthetized horses during the alveolar recruitment manoeuvre (ARM).

STUDY DESIGN: Experimental study in which a series of treatments were administered in a fixed order on one occasion.

ANIMALS: Five adult Warmblood horses.

METHODS: Animals were anaesthetized (xylazine, midazolam-ketamine, isoflurane), placed in dorsal recumbency and ventilated with 100% oxygen using peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP) of 20 cmH2 O and 0 cmH2 O, respectively. Thoracic electrical impedance tomography (EIT), spirometry and routine anaesthesia monitoring were performed. At 90 minutes after induction of anaesthesia, PIP and PEEP were increased in steps of 5 cmH2 O to 50 cmH2 O and 30 cmH2 O, respectively, and then decreased to baseline values. Each step lasted 10 minutes. Data were recorded and functional EIT images were created using three breaths at the end of each step. Arterial blood samples were analysed. Values for left-to-right and sternal-to-dorsal centre of ventilation (COV), lung compliances and Bohr dead space were calculated.

RESULTS: Distribution of ventilation drifted leftward and dorsally during recruitment. Mean±standard deviation (SD) values at baseline and highest airway pressures, respectively, were 49.9±0.7% and 48.0±0.6% for left-to-right COV (p=0.009), and 46.3±2.0% and 54.6±2.0% for sternal-to-dorsal COV (p=0.0001). Compliance of dependent lung regions and PaO2 increased, whereas compliance of non-dependent lung regions decreased during ARM and then returned to baseline (p<0.001). Bohr dead space decreased after ARM (p=0.007). Interestingly, PaO2 correlated to the compliance of the dependent lung (r2 =0.71, p<0.001).

CONCLUSIONS AND CLINICAL RELEVANCE: The proportion of tidal volume distributed to dependent and left lung regions increased during ARM, presumably as a result of opening atelectasis. Monitoring compliance of the dependent lung with EIT may substitute PaO2 measurements during ARM to identify an optimal PEEP.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app