Management of unstable distal third clavicle fractures: clinical and radiological outcomes of the arthroscopy-assisted conoid ligament reconstruction and fracture cerclage with sutures.

INTRODUCTION: Surgical treatment is indicated for the management of Neer type IIB fractures of the distal third of the clavicle. The aim of this study was to assess the clinical and radiological outcomes, in cases of unstable distal third clavicle fractures managed by means of an arthroscopy-assisted conoid ligament reconstruction and fracture cerclage with sutures.

METHODS: Nine patients with unstable distal third clavicle fractures (Neer type IIB) managed arthroscopically by means of a conoid ligament reconstruction and fracture cerclage with sutures, between 2008 and 2012, were included. The QoL was evaluated at the last follow-up visit, by means of the Health Survey questionnaire (SF36), the visual analogue scale (VAS) for pain, the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, the constant score, and a Global Satisfaction scale (from 0 to 10). The mean time from fracture fixation until radiological union, the development of hardware loosening, nonunion, infections, and hardware skin discomfort were evaluated.

RESULTS: The mean age was 36 [21-48] years old. The mean [range] time from surgery until the last follow-up visit was 49 [46-52] months. Values of the questionnaires assessed at the last follow-up visit were: (1) physical SF36 score (50.72 ± 6.88); (2) mental SF36 score (50.92 ± 11.65); (3) VAS for pain (1.86 ± 1.35); (4) DASH questionnaire (11.97 ± 7.03); (5) constant score (89.67 ± 8.55), and (6) Global Satisfaction (8.17 ± 0.98). The mean time elapsed from fracture fixation to radiological union was 8.41 ± 3.26 months. Hardware loosening was observed in none of the patients. Nonunion was observed in 11.11% (1/9) of the patients. Hardware skin discomfort was observed in 11.11% (1/9) of the patients.

CONCLUSION: Patients with unstable distal third clavicle fractures managed by means of an arthroscopy-assisted conoid ligament reconstruction and fracture cerclage with sutures may have good clinical and radiological outcomes, with no need for a second surgical procedure to remove any metal hardware.

LEVEL OF EVIDENCE: Therapeutic; case series, Level IV.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app