We have located links that may give you full text access.
SF-6D utility values for the better- and worse-seeing eye for health states based on the Snellen equivalent in patients with age-related macular degeneration.
PloS One 2017
OBJECTIVE: Economic evaluations in wet age-related macular degeneration (ARMD) is hampered as often utility values for solely one eye are used, mostly the better-seeing eye (BSE). Moreover, frequently chosen methods rely on patient values and/or disease specific measures, while economic evaluations prefer generic quality of life (QoL) measures based on societal preferences. The generic QoL utility instrument EQ-5D has shown to be insensitive for differences in visual acuity. The aim of this study was therefore to provide societal utility values, using the generic SF-6D, for health states acknowledging both BSE and worse-seeing eye (WSE).
METHODS: SF-6D utility values of 191 ARMD patients (≥65 years) with 153 follow-up measures at 1 year were used to fill health states defined by the combination of BSE and WSE using Snellen equivalents; no visual loss (≥20/40), mild-moderate (<20/40->20/200) and severe (≤20/200).
RESULTS: QoL utilities were estimated for the SF-6D, ranging from 0.740 for ARMD patients without visual loss to 0.684 for patients with a combination of mild-moderate visual loss in their BSE and severe visual loss in their WSE.
CONCLUSION: Societal utility values are provided for ARMD patients using the generic QoL instrument SF-6D for visual acuity health states based on both BSE and WSE. The range of the values is smaller than previous elicited utilities with the disease-specific VisQoL. Besides, the utility values are placed on a more realistic position on the utility scale, and SF-6D utility values avoid the problem associated with the interpretation of disease-specific utility values.
METHODS: SF-6D utility values of 191 ARMD patients (≥65 years) with 153 follow-up measures at 1 year were used to fill health states defined by the combination of BSE and WSE using Snellen equivalents; no visual loss (≥20/40), mild-moderate (<20/40->20/200) and severe (≤20/200).
RESULTS: QoL utilities were estimated for the SF-6D, ranging from 0.740 for ARMD patients without visual loss to 0.684 for patients with a combination of mild-moderate visual loss in their BSE and severe visual loss in their WSE.
CONCLUSION: Societal utility values are provided for ARMD patients using the generic QoL instrument SF-6D for visual acuity health states based on both BSE and WSE. The range of the values is smaller than previous elicited utilities with the disease-specific VisQoL. Besides, the utility values are placed on a more realistic position on the utility scale, and SF-6D utility values avoid the problem associated with the interpretation of disease-specific utility values.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app