P.F.C Sigma ® cruciate retaining fixed-bearing versus mobile-bearing knee arthroplasty: a prospective comparative study with minimum 10-year follow-up.
AIMS: To prospectively compare long-term clinical and radiological outcomes following a cruciate retaining fixed-bearing (FB) and a mobile-bearing (MB) primary total knee replacement (TKR).
METHODS: We prospectively reviewed 113 TKRs in 99 patients (14 bilateral) with a PFC sigma cruciate retaining rotating platform system, at an average follow-up of 11.1 years (range 10-12). Results were contrasted with those from 89 TKRs in 72 patients (17 bilateral) with a PFC sigma cruciate fixed-bearing prosthesis, at an average follow-up of 12.1 years (range 10-14.1). Outcomes collected included pre- and post-operative range of motion, Oxford Knee Scores, complications encountered, as well as radiographical assessments of polyethylene wear.
RESULTS: In the MB group, mean Oxford Knee Scores improved from 16 pre-operatively to 42 at final follow-up. The mean range of motion was 115° (75-130). In the FB group, mean Oxford Knee Scores improved from 16.2 pre-operatively to 42.5 at final follow-up. The mean range of motion was 111.2 (80-135) degrees at final follow-up.
CONCLUSION: We failed to elicit an objectively demonstrable clinical difference between the MB- and FB-implanted knees. Similarly, radiological benefits of the MB implants with regard to polyethylene wear were not evident at a minimum 10-year follow-up.
METHODS: We prospectively reviewed 113 TKRs in 99 patients (14 bilateral) with a PFC sigma cruciate retaining rotating platform system, at an average follow-up of 11.1 years (range 10-12). Results were contrasted with those from 89 TKRs in 72 patients (17 bilateral) with a PFC sigma cruciate fixed-bearing prosthesis, at an average follow-up of 12.1 years (range 10-14.1). Outcomes collected included pre- and post-operative range of motion, Oxford Knee Scores, complications encountered, as well as radiographical assessments of polyethylene wear.
RESULTS: In the MB group, mean Oxford Knee Scores improved from 16 pre-operatively to 42 at final follow-up. The mean range of motion was 115° (75-130). In the FB group, mean Oxford Knee Scores improved from 16.2 pre-operatively to 42.5 at final follow-up. The mean range of motion was 111.2 (80-135) degrees at final follow-up.
CONCLUSION: We failed to elicit an objectively demonstrable clinical difference between the MB- and FB-implanted knees. Similarly, radiological benefits of the MB implants with regard to polyethylene wear were not evident at a minimum 10-year follow-up.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app