BACKGROUND: Internal fixation modalities of unstable (>50 percent articular involvement) middle phalangeal volar lip fracture-dislocations include interfragmentary screw and volar buttress plating. This study investigates the mechanical properties (yield strength, ultimate tensile strength, and stiffness) of interfragmentary screw (IS), simple buttress plating (BP) and buttress plating with subchondral screw (BP+S).
METHODS: Fifteen cadaveric digits (5 index, 5 middle, and 5 ring) were prepared by excising its skin envelope and flexor tendons while preserving the structures around the proximal interphalangeal joint. An oblique osteotomy involving 50 percent of the articular surface was performed, and this was fixed with based on its study group: interfragmentary screw (IS), simple buttress plating (BP) and buttress plating with subchondral screw (BP+S). These specimens were then loaded to failure.
RESULTS: Yield strength was as follows: BP+S (33.5±9.76 N), IS (13.6±5.46 N), and BP (8.1±3.84 N). Ultimate tensile strength was as follows: BP+S (49.1±21.4 N), IS (15.6±5.19 N), and BP (8.86±3.99 N). Stiffness was as follows: BP+S (4.77±1.32 N/mm), IS (2.44±0.86 N/mm), and BP (1.84±0.71 N/mm).
CONCLUSIONS: A buttress plate and screw construct confers significantly more stability than either interfragmentary screw or buttress plate only fixation in an experimental model.
METHODS: Fifteen cadaveric digits (5 index, 5 middle, and 5 ring) were prepared by excising its skin envelope and flexor tendons while preserving the structures around the proximal interphalangeal joint. An oblique osteotomy involving 50 percent of the articular surface was performed, and this was fixed with based on its study group: interfragmentary screw (IS), simple buttress plating (BP) and buttress plating with subchondral screw (BP+S). These specimens were then loaded to failure.
RESULTS: Yield strength was as follows: BP+S (33.5±9.76 N), IS (13.6±5.46 N), and BP (8.1±3.84 N). Ultimate tensile strength was as follows: BP+S (49.1±21.4 N), IS (15.6±5.19 N), and BP (8.86±3.99 N). Stiffness was as follows: BP+S (4.77±1.32 N/mm), IS (2.44±0.86 N/mm), and BP (1.84±0.71 N/mm).
CONCLUSIONS: A buttress plate and screw construct confers significantly more stability than either interfragmentary screw or buttress plate only fixation in an experimental model.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app