Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Healthcare Utilization and Expenditures Associated With Appropriate and Inappropriate Implantable Defibrillator Shocks.

BACKGROUND: In patients with implantable cardioverter-defibrillators, healthcare utilization (HCU) and expenditures related to shocks have not been quantified.

METHODS AND RESULTS: We performed a retrospective cohort study of patients with implantable cardioverter-defibrillators identified from commercial and Medicare supplemental claims databases linked to adjudicated shock events from remote monitoring data. A shock event was defined as ≥1 spontaneous shocks delivered by an implanted device. Shock-related HCU was ascertained from inpatient and outpatient claims within 7 days following a shock event. Shock events were adjudicated and classified as inappropriate or appropriate, and HCU and expenditures, stratified by shock type, were quantified. Of 10 266 linked patients, 963 (9.4%) patients (61.3±13.6 years; 81% male) had 1885 shock events (56% appropriate, 38% inappropriate, and 6% indeterminate). Of these events, 867 (46%) had shock-related HCU (14% inpatient and 32% outpatient). After shocks, inpatient cardiovascular procedures were common, including echocardiography (59%), electrophysiology study or ablation (34%), stress testing (16%), and lead revision (11%). Cardiac catheterization was common (71% and 51%), but percutaneous coronary intervention was low (6.5% and 5.0%) after appropriate and inappropriate shocks. Expenditures related to appropriate and inappropriate shocks were not significantly different.

CONCLUSIONS: After implantable cardioverter-defibrillator shock, related HCU was common, with 1 in 3 shock events followed by outpatient HCU and 1 in 7 followed by hospitalization. Use of invasive cardiovascular procedures was substantial, even after inappropriate shocks, which comprised 38% of all shocks. Implantable cardioverter-defibrillator shocks seem to trigger a cascade of health care. Strategies to reduce shocks could result in cost savings.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app