Journal Article
Meta-Analysis
Review
Add like
Add dislike
Add to saved papers

Diagnostic Performance of Prostate Imaging Reporting and Data System Version 2 for Detection of Prostate Cancer: A Systematic Review and Diagnostic Meta-analysis.

European Urology 2017 August
CONTEXT: In 2015, the updated Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for the detection of prostate cancer (PCa) was established. Since then, several studies assessing the value of PI-RADSv2 have been published.

OBJECTIVE: To review the diagnostic performance of PI-RADSv2 for the detection of PCa.

EVIDENCE ACQUISITION: MEDLINE and EMBASE databases were searched up to December 7, 2016. We included diagnostic accuracy studies that used PI-RADSv2 for PCa detection, using prostatectomy or biopsy as the reference standard. The methodological quality was assessed by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of all studies were calculated. Results were pooled and plotted in a hierarchical summary receiver operating characteristic plot with further exploration using meta-regression and multiple subgroup analyses. Head-to-head comparison between PI-RADSv1 and PI-RADSv2 was performed for available studies.

EVIDENCE SYNTHESIS: Twenty-one studies (3857 patients) were included. The pooled sensitivity was 0.89 (95% confidence interval [CI] 0.86-0.92) with specificity of 0.73 (95% CI 0.60-0.83) for PCa detection. Proportion of patients with PCa, magnetic field strength, and reference standard were significant factors affecting heterogeneity (p<0.01). Multiple subgroup analyses showed consistent results. In six studies performing head-to-head comparison, PI-RADSv2 demonstrated higher pooled sensitivity of 0.95 (95% CI 0.85-0.98) compared with 0.88 (95% CI 0.80-0.93) for PI-RADSv1 (p=0.04). However, the pooled specificity was not significantly different (0.73 [95% CI 0.47-0.89] vs 0.75 [95% CI 0.36-0.94], respectively; p=0.90).

CONCLUSIONS: PI-RADSv2 shows good performance for the detection of PCa. PI-RADSv2 has higher pooled sensitivity than PI-RADSv1 without significantly different specificity.

PATIENT SUMMARY: We reviewed all previous studies using Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for prostate cancer detection. We found that the updated PI-RADSv2 shows significant improvement compared with the original PI-RADSv1.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app