JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Development of a Biocompatible In-Tube Solid-Phase Microextraction Device: A Sensitive Approach for Direct Analysis of Single Drops of Complex Matrixes.

Analytical Chemistry 2016 December 21
The aim of the current study is to develop a sensitive solid-phase microextraction (SPME) device for direct and rapid analysis of untreated complex matrixes (i.e., single drop of the samples, V ≤ 2 μL). A thin layer of a biocompatible nanostructured polypyrrole (PPy) was electrochemically deposited inside a medical grade spinal needle, minimizing the matrix effect. Microsampling was facilitated by loading the sample inside the in-tube SPME device (withdraw of sample via plunger), where extraction was performed under static conditions. Two strategies were used for analysis of the compounds including offline desorption and running the extract to the liquid chromatograph-tandem mass spectrometer (LC-MS/MS) or direct coupling of the in-tube SPME device to the MS. Given the high surface-area-to-volume ratio of the coating, a short equilibrium time (i.e., t ≤ 2 min) was obtained. The whole analytical procedure (i.e., extraction, rinsing, desorption, and LC-MS/MS analysis) was performed within 10 min by LC-MS/MS, and 3 min by in-tube-MS/MS. Possible matrix effects for the prepared device were evaluated in whole blood samples at three levels of concentration, and encouraging results were achieved in the range of 83-120%. The obtained results, no matrix effect, are attributed to the smooth surface and small pore size of the biocompatible PPy coating, which was prepared in the presence of cetyltrimethylammonium bromide (CTAB) surfactant. The in-tube SPME device was shown to be very sensitive, with high total recoveries obtained for all compounds in phosphate-buffered saline (PBS) and urine samples owing to the large volume and capacity of the coating. Subnanogram per milliliter levels of detection were achieved for urine samples, and low nanogram per milliliter levels were found in whole blood samples for all studied compounds with a high protein binding index. Rapid analysis of whole blood samples was achieved without need of any pretreatment or manipulation of sample, revealing the developed in-tube SPME device as an ideal probe for forensic application, drug monitoring, and point-of care-diagnosis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app