Performance of HBsAg quantification assays for detection of Hepatitis B virus genotypes and diagnostic escape-variants in clinical samples.

BACKGROUND: The impact of hepatitis B virus (HBV) genomic variability on the measurement of HBsAg level has been poorly evaluated.

OBJECTIVE: This study was designed to compare the performance of all the available assays measuring HBsAg level in this setting.

STUDY DESIGN: A large selection of wild type HBV genotypes (n=184) and HBsAg strains harboring mutations in the S gene (n=81) from clinical samples was studied with three HBsAg quantification assays: Architect HBsAg (Abbott), LiaisonXL Murex HBsAg Quant (DiaSorin) and the Elecsys HBsAgII (Roche).

RESULTS: The overall percentage of positive results was 99.2% for Abbott, 98.9% for DiaSorin and 98.1% for Roche. Abbott and Roche assays provided an excellent concordance in HBsAg quantification (global mean bias of -0.006 logIU/mL). By contrast, DiaSorin underestimated HBsAg level with values 0.112 logIU/ml and 0.103 logIU/ml lower than Abbott and Roche, respectively. By contrast, DiaSorin slightly over quantified gtC (2.5% over the expected value) while Abbott provided values 6.2% lower than expected and 16.2% lower than what observed for the other genotypes. HBsAg quantitative assays were influenced by HBs protein substitutions irrespective to the genotype but no specific protein pattern that would particularly impair the quantification by one technique has been identified. However, Roche seemed to be particularly impacted by substitutions at 145 residue: 75% of under quantified samples carried a substituted 145 residue.

CONCLUSION: This head-to-head comparison indicates a good correlation between all current systems used to quantify HBsAg but clearly shows an influence of both the genotype and the presence of "a" determinant variants in the absolute quantification of HBsAg. While these discrepancies may not translate into major clinical consequence, they may explain an absence of detection of weak concentration of HBsAg on some systems.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app