Epicardial Catheter Ablation of Ventricular Tachycardia.
Cardiac Electrophysiology Clinics 2017 March
Over the last two decades, epicardial catheter ablation has evolved into a practical approach for treatment of ventricular tachycardia (VT). There are certain considerations when performing this procedure. First, presence of epicardial fat can diminish peak-to-peak electrogram amplitude and also impede radiofrequency energy delivery. Hence, epicardial VT ablation should be performed with cooled-tip radiofrequency using reduced irrigation flow within a relatively 'dry' pericardial milieu. Furthermore, catheter orientation is key when performing epicardial ablation. Lastly, hemo-pericardium remains the most common major adverse event of epicardial ablation and its presenting timeline may be used to identify the precise nature of this complication.