[Comparison of the effects of different side-cut angles on corneal biomechanical properties after femtosecond laser assisted-laser in situ keratomileusis].

Objective: To evaluate the effects of side-cut angles on corneal biomechanical properties after femtosecond laser assisted-laser in situ keratomileusis (FS-LASIK). Methods: In this clinical control study, 97 right eyes of 97 patients with myopia and myopic astigmatism undergoing FS-LASIK surgery were included randomly. Two types of side-cut angles were designed for the flap, 90° in 48 eyes and 130° in 49 eyes. The values of corneal resistance factor (CRF), cornea hysteresis (CH) and 37 biomechanical waveform parameters were measured using the ocular response analyzer preoperatively and at 1 and 3 months postoperatively. The comparison between the two groups at different follow-up time points was made with one-way analysis of variance, and the comparison among different follow-up time points in each group was performed with the repeated measures analysis of variance. Results: The mean CRF, CH, p area, h, dive1, dive2, w11 and w21 in both groups showed significant reduction at 1 month postoperatively (group 90°: CRF 10.49 vs. 6.85, CH 10.02 vs. 7.55, p1 area 3 537.54 vs. 1 918.07, h1 404.74 vs. 283.25, dive1 350.63 vs. 243.33, w11 10.50 vs. 7.58. group 130°: CRF 10.14 vs. 6.38, CH 9.93 vs. 7.13, p1 area 3 498.93 vs. 2 038.74, h1 411.93 vs. 304.49, dive1 352.51 vs. 265.12, w11 10.55 vs. 7.78. P< 0.001) . The mean CRF, CH, p area, w, h, dive1 and dive2 in both groups showed significant reduction at 3 months postoperatively (group 90°: CRF 10.49 vs. 6.60, CH 10.02 vs. 7.65, p1 area 3537.54 vs. 2042.91, h1 404.74 vs. 307.77, dive1 350.63 vs. 263.33, w11 10.50 vs. 7.58. group 130°: CRF 10.14 vs. 6.45, CH 9.93 vs. 7.67, p1 area 3 498.93 vs. 2 187.97, h1 411.93 vs. 327.39, dive1 352.51 vs. 284.26, w11 10.55 vs. 7.61. P< 0.001). The mean path in both groups showed significant increase at 1 and 3 months postoperatively (group 90°: path1 23.14 vs. 30.50 vs. 30.79. group 130°: path1 24.12 vs. 32.18 vs. 31.49. P< 0.001). The mean aplhf, bindex, dive2 and path2 between both groups at 1 month postoperatively showed significant difference ( F= 8.609, 7.482, 5.238, 4.885, P <0.05). The mean path11 between both groups at 3 months postoperatively showed significant difference ( F= 6.160, P <0.05). Conclusions: Corneal biomechanical properties significantly decrease after FS-LASIK, and different side-cut angles have some effect on corneal biomechanical properties after FS-LASIK. The corneal deformation is more stable after flap creation with an obtuse side-cut angle making the cornea under stress. Combined with waveform parameters of the ocular response analyzer, more subtle changes of corneal biomechanical properties can be found. (Chin J Ophthalmol, 2017, 53:23-32) .

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app