We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
Usefulness of 3D echocardiographic parameters of tricuspid valve morphology to predict residual tricuspid regurgitation after tricuspid annuloplasty.
European Heart Journal Cardiovascular Imaging 2017 July 2
Aims: Tricuspid valve (TV) annuloplasty is an effective treatment for tricuspid regurgitation (TR). However, the impact of TV morphology on outcome of TV annuloplasty remains unknown. We sought to investigate the relationship between preoperative TV morphology and residual TR after annuloplasty.
Methods and Results: Two-dimensional transthoracic and three-dimensional (3D) transesophageal echocardiography were performed in 97 patients with functional TR before and after surgery. 3D quantitative assessment including annular dimension, tenting height and volume, and lengths and tethering angles of the 3 leaflets was performed. The TV morphological score was derived from the preoperative 3D echocardiography to score a leaflet mobility, leaflet thickening, subvalvular thickening, and calcification. TR severity was determined by the averaged vena contracta measured from the apical and parasternal inflow views. Multivariable analysis revealed that a shorter total leaflet length (P = 0.007), larger tenting volume (P < 0.001), and higher TV morphological score (P < 0.001) were independently associated with residual TR. A TV-Echo score was determined as a sum of points based on receiver operator characteristics analysis: total leaflet length >61.0 mm, 61.0 to 53.5 mm, and <53.5 mm; tenting volume <2.3 mL, 2.3 to 3.5 mL, and >3.5 mL; and TV morphological score <7, 7 to 18, and >18; each variable was associated with 0 and 1 point and 2 points, respectively. The TV-Echo score ≥2 was associated with significant residual TR with a sensitivity of 85.7% and a specificity of 71.0%.
Conclusion: In addition to tethering and short length of the leaflets, TV morphological abnormality predicted residual TR after TV annuloplasty.
Methods and Results: Two-dimensional transthoracic and three-dimensional (3D) transesophageal echocardiography were performed in 97 patients with functional TR before and after surgery. 3D quantitative assessment including annular dimension, tenting height and volume, and lengths and tethering angles of the 3 leaflets was performed. The TV morphological score was derived from the preoperative 3D echocardiography to score a leaflet mobility, leaflet thickening, subvalvular thickening, and calcification. TR severity was determined by the averaged vena contracta measured from the apical and parasternal inflow views. Multivariable analysis revealed that a shorter total leaflet length (P = 0.007), larger tenting volume (P < 0.001), and higher TV morphological score (P < 0.001) were independently associated with residual TR. A TV-Echo score was determined as a sum of points based on receiver operator characteristics analysis: total leaflet length >61.0 mm, 61.0 to 53.5 mm, and <53.5 mm; tenting volume <2.3 mL, 2.3 to 3.5 mL, and >3.5 mL; and TV morphological score <7, 7 to 18, and >18; each variable was associated with 0 and 1 point and 2 points, respectively. The TV-Echo score ≥2 was associated with significant residual TR with a sensitivity of 85.7% and a specificity of 71.0%.
Conclusion: In addition to tethering and short length of the leaflets, TV morphological abnormality predicted residual TR after TV annuloplasty.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app