Add like
Add dislike
Add to saved papers

Numerical investigations of flow and passive pollutant exposure in high-rise deep street canyons with various street aspect ratios and viaduct settings.

Vehicular pollutant exposure of residents and pedestrians in high-rise deep street canyons with viaducts and noise barriers requires special concerns because the ventilation capacity is weak and the literature reported inconsistent findings on flow patterns as aspect ratios (building height/street width, H/W) are larger than 2. By conducting computational fluid dynamics (CFD) simulations coupled with the intake fraction iF and the daily pollutant exposure Et , this paper investigates the impact of street aspect ratios, viaducts and noise barriers on the flow and vehicular passive pollutant exposure in full-scale street canyons (H/W=1-6, W=24m). iF represents the fraction of total emissions inhaled by a population (1ppm=10-6 ), while Et means the extent of human beings' contact with pollutants within one day. CFD methodologies of passive pollutant dispersion modeling are successfully validated by wind tunnel data in Meroney et al. (1996). As a novelty, the two-main-vortex pattern start appearing in full-scale street canyons as H/W changes from 4 to 5, however previous studies using wind-tunnel-scale models (H=6cm) reported two to five vortexes as H/W=2-5. This finding is validated by both smoke visualization in scale-model outdoor field experiments (H=1.2m, W=0.6m) and CFD simulations of Reynolds number independence. Cases with two main vortexes (H/W=5-6) experience much larger daily pollutant exposure (~103 -104 mg/m3 /day) than those with single main vortex as H/W=1-4 (~101 -102 mg/m3 /day). Moreover leeward-side pollutant exposures are much larger than windward-side as H/W=1-4 while oppositely as H/W=5-6. Assuming a general population density, the total iF is 485-803ppm as H/W=1, 2020-12051ppm as H/W=2-4, and 51112-794026ppm as H/W=5-6. With a single elevated pollutant source, cases with viaducts experience significantly smaller pollutant exposures than cases without viaducts. Road barriers slightly increase pollutant exposure in near-road buildings with H/W=1 while reduce a little as H/W=3 and 5. Two-source cases can experience 2.60-5.52 times pollutant exposure as great as single-source cases.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app