BACKGROUND: Anastomotic leak (AL) increases costs and cancer recurrence. Studies show decreased AL with side-to-side stapled anastomosis (SSA), but none identify risk factors within SSAs. We hypothesized that stapler characteristics and closure technique of the common enterotomy affect AL rates.
METHODS: Retrospective review of bowel SSAs was performed. Data included stapler brand, staple line oversewing, and closure method (handsewn, HC; linear stapler [Barcelona technique], BT; transverse stapler, TX). Primary endpoint was AL. Statistical analysis included Fisher's test and logistic regression.
RESULTS: 463 patients were identified, 58.5% BT, 21.2% HC, and 20.3% TX. Covidien staplers comprised 74.9%, Ethicon 18.1%. There were no differences between stapler types (Covidien 5.8%, Ethicon 6.0%). However, AL rates varied by common side closure (BT 3.7% vs. TX 10.6%, p = 0.017), remaining significant on multivariate analysis.
CONCLUSION: Closure method of the common side impacts AL rates. Barcelona technique has fewer leaks than transverse stapled closure. Further prospective evaluation is recommended.
METHODS: Retrospective review of bowel SSAs was performed. Data included stapler brand, staple line oversewing, and closure method (handsewn, HC; linear stapler [Barcelona technique], BT; transverse stapler, TX). Primary endpoint was AL. Statistical analysis included Fisher's test and logistic regression.
RESULTS: 463 patients were identified, 58.5% BT, 21.2% HC, and 20.3% TX. Covidien staplers comprised 74.9%, Ethicon 18.1%. There were no differences between stapler types (Covidien 5.8%, Ethicon 6.0%). However, AL rates varied by common side closure (BT 3.7% vs. TX 10.6%, p = 0.017), remaining significant on multivariate analysis.
CONCLUSION: Closure method of the common side impacts AL rates. Barcelona technique has fewer leaks than transverse stapled closure. Further prospective evaluation is recommended.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app