We have located links that may give you full text access.
Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA.
Journal of Biomedical Physics & Engineering 2016 December
BACKGROUND: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.
OBJECTIVE: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV were evaluated for the Digimouse voxel phantom incorporated in Monte Carlo code FLUKA. The organ sources considered in this study were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal, eye and brain. The considered target organs were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal and brain. Eye was considered as a target organ only for eye as a source organ. Organ compositions and densities were adopted from International Commission on Radiological Protection (ICRP) publication number 110.
RESULTS: Evaluated organ masses and SAF values are presented in tabular form. It is observed that SAF values decrease with increasing the source-to-target distance. The SAF value for self-irradiation decreases with increasing photon energy. The SAF values are also found to be dependent on the mass of target in such a way that higher values are obtained for lower masses. The effect of composition is highest in case of target organ lungs where mass and estimated SAF values are found to have larger differences.
CONCLUSION: These SAF values are very important for absorbed dose calculation for various organs of a mouse.
OBJECTIVE: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV were evaluated for the Digimouse voxel phantom incorporated in Monte Carlo code FLUKA. The organ sources considered in this study were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal, eye and brain. The considered target organs were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal and brain. Eye was considered as a target organ only for eye as a source organ. Organ compositions and densities were adopted from International Commission on Radiological Protection (ICRP) publication number 110.
RESULTS: Evaluated organ masses and SAF values are presented in tabular form. It is observed that SAF values decrease with increasing the source-to-target distance. The SAF value for self-irradiation decreases with increasing photon energy. The SAF values are also found to be dependent on the mass of target in such a way that higher values are obtained for lower masses. The effect of composition is highest in case of target organ lungs where mass and estimated SAF values are found to have larger differences.
CONCLUSION: These SAF values are very important for absorbed dose calculation for various organs of a mouse.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app