Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study.

OBJECTIVES: The goal of this study is to compare the fatigue strength of a locking intramedullary nail (LN) construct with a double locking plate (DLP) construct in comminuted proximal extra-articular tibia fractures.

METHODS: Eight pairs of fresh frozen cadaveric tibias with low bone mineral density [age: 80 ± 7 (SD) years, T-score: -2.3 ± 1.2] were used. One tibia from each pair was fixed with LN, whereas the contralateral side was fixed with DLP for complex extra-articular multifragmentary metaphyseal fractures (simulating OTA 41-A3.3). Specimens were cyclically loaded under compression simulating single-leg stance by staircase method out to 260,000 cycles. Every 2500 cycles, localized gap displacements were measured with a 3D motion tracking system, and x-ray images of the proximal tibia were acquired. To allow for mechanical settling, initial metrics were calculated at 2500 cycles. The 2 groups were compared regarding initial construct stiffness, initial medial and lateral gap displacements, stiffness at 30,000 cycles, medial and lateral gap displacements at 30,000 cycles, failure load, number of cycles to failure, and failure mode. Failure metrics were reported for initial and catastrophic failures.

RESULTS: DLP constructs exhibited higher initial stiffness and stiffness at 30,000 cycles compared with LN constructs (P < 0.03). There were no significant differences between groups for loads at failure or cycles to failure.

CONCLUSIONS: For the fixation of extra-articular proximal tibia fractures, a LN provides a similar fatigue performance to double locked plates. The locked nail could be safely used for fixation of proximal tibia fractures with the advantage of limited extramedullary soft tissue damage.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app