We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Development of a new assessment tool for cervical myelopathy using hand-tracking sensor: Part 2: normative values.
European Spine Journal 2017 April
PURPOSE: To set a baseline measurement of the number of hand flexion-extension cycles and analyse the degree of motion in young healthy individuals, measured by leap motion controller (LMC), besides describing gender and dominant hand differences.
METHODS: Fifty healthy participants were asked to fully grip-and-release their dominant hand as rapidly as possible for a maximum of 3 min or until subjects fatigued, while wearing a non-metal wrist splint. Participants also performed a 15-s grip-and-release test. An assessor blindly counted the frequency of grip-and-release cycles and magnitude of motion from the LMC data.
RESULTS: The mean number of the 15-s G-R cycles recorded by LMC was: 47.7 ± 6.5 (test 1, LMC); and 50.2 ± 6.5 (test 2, LMC). In the 3-min test, the total number of hand flexion-extension cycles and the degree of motion decreased as the person fatigued. However, the decline in frequency preceded that of motion's magnitude. The mean frequency of cycles per 10-s interval decreased from 35.4 to 26.6 over the 3 min. Participants reached fatigue from 59.38 s; 43 participants were able to complete the 3-min test.
CONCLUSIONS: Normative values of the frequency of cycles and extent of motion for young healthy individuals, aged 18-35 years, are provided. Future work is needed to establish values in a wider age range and in a clinical setting.
METHODS: Fifty healthy participants were asked to fully grip-and-release their dominant hand as rapidly as possible for a maximum of 3 min or until subjects fatigued, while wearing a non-metal wrist splint. Participants also performed a 15-s grip-and-release test. An assessor blindly counted the frequency of grip-and-release cycles and magnitude of motion from the LMC data.
RESULTS: The mean number of the 15-s G-R cycles recorded by LMC was: 47.7 ± 6.5 (test 1, LMC); and 50.2 ± 6.5 (test 2, LMC). In the 3-min test, the total number of hand flexion-extension cycles and the degree of motion decreased as the person fatigued. However, the decline in frequency preceded that of motion's magnitude. The mean frequency of cycles per 10-s interval decreased from 35.4 to 26.6 over the 3 min. Participants reached fatigue from 59.38 s; 43 participants were able to complete the 3-min test.
CONCLUSIONS: Normative values of the frequency of cycles and extent of motion for young healthy individuals, aged 18-35 years, are provided. Future work is needed to establish values in a wider age range and in a clinical setting.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app