Add like
Add dislike
Add to saved papers

Enhancing analysis throughput, sensitivity and specificity in LC/ESI-MS/MS assay of plasma 25-hydroxyvitamin D 3 by derivatization with triplex 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD) isotopologues.

The plasma/serum concentration of 25-hydroxyvitamin D3 [25(OH)D3 ] is a diagnostic index for vitamin D deficiency/insufficiency, which is associated with a wide range of diseases, such as rickets, cancer and diabetes. We have reported that the derivatization with 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD) works well in the liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) assay of the serum/plasma 25(OH)D3 for enhancing the sensitivity and the separation from a potent interfering metabolite, 3-epi-25-hydroxyvitamin D3 [3-epi-25(OH)D3 ]. However, enhancing the analysis throughput remains an issue in the LC/ESI-MS/MS assay of 25(OH)D3 . The most obvious restriction of the LC/MS/MS throughput is the chromatographic run time. In this study, we developed an enhanced throughput method for the determination of the plasma 25(OH)D3 by LC/ESI-MS/MS combined with the derivatization using the triplex (2 H0 -,2 H3 - and2 H6 -) DAPTAD isotopologues. After separate derivatization with 1 of 3 different isotopologues, the 3 samples were combined and injected together into LC/ESI-MS/MS. Based on the mass differences between the isotopologues, the derivatized 25(OH)D3 in the 3 different samples were quantified within a single run. The developed method tripled the hourly analysis throughput without sacrificing assay performance, i.e., ease of pretreatment of plasma sample (only deproteinization), limit of quantification (1.0ng/mL when a 5μL-plasma was used), precision (intra-assay RSD≤5.9% and inter-assay RSD≤5.5%), accuracy (98.7-102.2%), matrix effects, and capability of separating from an interfering metabolite, 3-epi-25(OH)D3 . The multiplexing of samples by the isotopologue derivatization was applied to the analysis of plasma samples of healthy subjects and the developed method was proven to have a satisfactory applicability.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app