We have located links that may give you full text access.
Establishing the standard method of cochlear implant in Rongchang pig.
Acta Oto-laryngologica 2017 May
CONCLUSIONS: In this investigation, a large mammal, Rongchang pigs were used to successfully establish a research platform for cochlear implant study on the routine use of it in clinic.
OBJECTIVE: The aim of this study was to establish a standard method of cochlear implant in a large mammal-pig.
METHODS: Rongchang pigs were selected, then divided into two groups: normal-hearing group (Mitf +/+) and mutation group with hearing loss (Mitf -/-). Cochlear implants were used and ABR and EABR were recorded. The implanted electrodes were observed by X-ray and HE stains.
RESULTS: The success with cochlear implant and the best electrode position could be defined in all animals, the coiling of the cochlea reached 1.5-1.75 turns. Immediately after the operation of cochlear implants, the ABR threshold of the operated ear (right) could not be derived for each frequency at 120 dB SPL. Moreover, 7 days after surgery, the low-frequency ABR threshold of the operated ear (right) could be derived partly at 100 dB SPL, but the high-frequency ABR threshold could not be derived at 120 dB SPL. Immediately or 1 week after cochlear implants, the EABR threshold was 90 CL in the Mitf +/+ group. This was obviously lower than the 190 CL in the Mitf -/- group.
OBJECTIVE: The aim of this study was to establish a standard method of cochlear implant in a large mammal-pig.
METHODS: Rongchang pigs were selected, then divided into two groups: normal-hearing group (Mitf +/+) and mutation group with hearing loss (Mitf -/-). Cochlear implants were used and ABR and EABR were recorded. The implanted electrodes were observed by X-ray and HE stains.
RESULTS: The success with cochlear implant and the best electrode position could be defined in all animals, the coiling of the cochlea reached 1.5-1.75 turns. Immediately after the operation of cochlear implants, the ABR threshold of the operated ear (right) could not be derived for each frequency at 120 dB SPL. Moreover, 7 days after surgery, the low-frequency ABR threshold of the operated ear (right) could be derived partly at 100 dB SPL, but the high-frequency ABR threshold could not be derived at 120 dB SPL. Immediately or 1 week after cochlear implants, the EABR threshold was 90 CL in the Mitf +/+ group. This was obviously lower than the 190 CL in the Mitf -/- group.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app