One-step CAD/CAM titanium cranioplasty after drilling template-assisted resection of intraosseous skull base meningioma: technical note.
Acta Neurochirurgica 2017 March
INTRODUCTION: Cranial defects following intra-osseous tumor removal may be large and require adequate reconstruction. CAD/CAM implants have been used for years to achieve an optimal cosmetic result. The disadvantage is that such implants require a second surgery. A preoperative virtual planning of resection margins and the simultaneously fabrication of the cranioplasty could be a possibility to subsume the steps tumor resection and cosmetic restoration to a single procedure.
METHODS: We present two cases of patients with complex intra-osseous spheno-orbital meningioma. Tumor resection was performed with the help of a drilling template in form of a frame. The template also served as a negative for the computer-designed cranioplasty. The devices were manufactured by DMD GmbH - Digital Medical Design/DDI-Group, Dortmund, Germany.
DISCUSSION: The usage of the template was highly practicable. Small adjustments in bone removal were necessary to achieve an optimal fitting of the implant. The 6-month follow-up showed for one patient a good and for one a satisfactory cosmetic result. No second surgery was necessary.
CONCLUSIONS: Drilling template application could contribute to challenging cases of large fronto-basal meningiomas with the aim of minimizing operation time and achieving a good esthetic outcome.
METHODS: We present two cases of patients with complex intra-osseous spheno-orbital meningioma. Tumor resection was performed with the help of a drilling template in form of a frame. The template also served as a negative for the computer-designed cranioplasty. The devices were manufactured by DMD GmbH - Digital Medical Design/DDI-Group, Dortmund, Germany.
DISCUSSION: The usage of the template was highly practicable. Small adjustments in bone removal were necessary to achieve an optimal fitting of the implant. The 6-month follow-up showed for one patient a good and for one a satisfactory cosmetic result. No second surgery was necessary.
CONCLUSIONS: Drilling template application could contribute to challenging cases of large fronto-basal meningiomas with the aim of minimizing operation time and achieving a good esthetic outcome.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app