The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children.
Pediatric Emergency Care 2019 April
OBJECTIVE: The goal of this study was to assess the accuracy of ultrasound-measured optic nerve sheath diameter (ONSD) as a screen for ventriculoperitoneal shunt failure.
METHODS: We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure.
RESULTS: We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively.
CONCLUSIONS: Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shunt malfunction who do not require neurosurgical intervention. Consideration of additional risk factors and a larger sample size may yield stronger results.
METHODS: We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure.
RESULTS: We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively.
CONCLUSIONS: Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shunt malfunction who do not require neurosurgical intervention. Consideration of additional risk factors and a larger sample size may yield stronger results.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app