Comparable Results With Porous Metal Augments in Combination With Either Cemented or Uncemented Cups in Revision Hip Arthroplasty: An Analysis of One Hundred Forty-Seven Revisions at a Mean of Five Years.
Journal of Arthroplasty 2017 May
BACKGROUND: Porous metal augments have been used successfully for management of large acetabular defects during revision hip arthroplasty. The purpose of this study was to retrospectively review and compare the clinical and radiographic outcomes of porous metal augments in cemented and uncemented acetabular revisions, all performed at the same institution.
METHODS: Using our institutional clinical databases, the clinical and radiological outcomes of 104 cemented and 43 uncemented acetabular revisions with metal augments, performed between 2006 and 2015, were studied and compared. Acetabular augments were used when preoperative and intraoperative findings indicated the presence of large acetabular defects that can hinder the stability of the revision implants.
RESULTS: At a mean follow-up of 60.1 months (range 12.7-112.1), a total of 5 cups (3.4%), being 3 cemented (2.8%) and 2 uncemented (4.6%), had shown signs of aseptic loosening with cup and augment migration and 4 of these have been re-revised (2.7%). At final follow-up, the European Quality of Life-5 Dimensions for generic health, and the Hip disability and Osteoarthritis Outcome Score (HOOS) parameters had improved substantially without any significant difference between fixation techniques.
CONCLUSION: Porous metal augments show comparable excellent radiographic and clinical mid-term outcomes when combined with cemented or uncemented cups in revision hip arthroplasty.
METHODS: Using our institutional clinical databases, the clinical and radiological outcomes of 104 cemented and 43 uncemented acetabular revisions with metal augments, performed between 2006 and 2015, were studied and compared. Acetabular augments were used when preoperative and intraoperative findings indicated the presence of large acetabular defects that can hinder the stability of the revision implants.
RESULTS: At a mean follow-up of 60.1 months (range 12.7-112.1), a total of 5 cups (3.4%), being 3 cemented (2.8%) and 2 uncemented (4.6%), had shown signs of aseptic loosening with cup and augment migration and 4 of these have been re-revised (2.7%). At final follow-up, the European Quality of Life-5 Dimensions for generic health, and the Hip disability and Osteoarthritis Outcome Score (HOOS) parameters had improved substantially without any significant difference between fixation techniques.
CONCLUSION: Porous metal augments show comparable excellent radiographic and clinical mid-term outcomes when combined with cemented or uncemented cups in revision hip arthroplasty.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app