Add like
Add dislike
Add to saved papers

The Development of a Representative Porcine Early-Onset Scoliosis Model With a Standalone Posterior Spinal Tether.

Spine Deformity 2017 January
STUDY DESIGN: In vivo analysis in a porcine model.

OBJECTIVES: To develop a porcine experimental scoliosis model representative of early-onset scoliosis (EOS) with the use of a radiopaque ultra-high molecular weight polyethylene (UHMWPE) posterior spinal tether.

SUMMARY OF BACKGROUND DATA: Large animal experimental scoliosis models with substantial growth potential are needed to test new fusionless scoliosis correction techniques. Previously described scoliosis models involve rib procedures, which violate the thoracic cage and affect subsequent corrective procedures. Models omitting these rib procedures have experienced difficulties in producing persistent three-dimensional structural deformities representative of EOS.

METHODS: Scoliosis was induced in 14 immature pigs using an asymmetric posterior radiopaque UHMWPE spinal tether fixated to an offset device at lumbar and thoracic levels. Radiographs were taken at 2-week intervals, and frontal and sagittal Cobb angles were measured. A tether release was performed at the 10-week follow-up, and the animals were observed for another 10 weeks.

RESULTS: Four animals had complications (infections and/or screw breakout) and were excluded from the study. Eight animals developed progressive curves with a mean frontal Cobb angle of 62°. A thoracic lordosis (34°) and a thoracolumbar kyphosis (22°) formed. CT analysis, acquired prior to tether release, showed a mean vertebral rotation of 37° at the apex with a mean vertebral wedge angle of 10°. After tether release, the frontal Cobb angles decreased to 46° at the 20-week follow-up. Sagittal curvature was not substantially affected after tether release.

CONCLUSIONS: We describe a large animal scoliosis model, which exhibits a substantial deformity in three planes without the use of rib procedures additional to a posterior spinal tether. The created deformities showed persistence after tether release. With the management of infection and enhancement of instrumentation stability, the creation of a valid model for testing new devices in fusionless scoliosis surgery seems feasible.

LEVEL OF EVIDENCE: Level V.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app