A Simplified Technique for Interventional Extracardiac Fontan.
PURPOSE: We report a simple technique for an interventional extracardiac Fontan (ECF) procedure.
DESCRIPTION: At the preparatory stage along with a bidirectional cavopulmonary connection (BCPC; cardiopulmonary bypass), a short piece of polytetrafluoroethylene (PTFE) tube graft is anastomosed to the inferior surface of the right pulmonary artery. Another longer PTFE graft is anastomosed to the transected inferior vena cava (IVC). A large medial opening in the lower PTFE graft is anastomosed to an atriotomy. These two PTFE tubes are anastomosed with a pericardial patch interposed between them. During the later interventional Fontan procedure, this pericardial patch is perforated using radiofrequency, and a covered stent is positioned entirely within the PTFE tubes, eliminating the window into the common atrium and leaving no intrapulmonary prosthetic material.
EVALUATION: The hemodynamics after the preparatory stage is similar to those following a BCPC, with uninterrupted flow from the IVC to the right atrium. On completion, there is a nonfenestrated Fontan circuit.
CONCLUSION: Our technique of interventional Fontan, anatomically and hemodynamically, mimics a standard ECF procedure.
DESCRIPTION: At the preparatory stage along with a bidirectional cavopulmonary connection (BCPC; cardiopulmonary bypass), a short piece of polytetrafluoroethylene (PTFE) tube graft is anastomosed to the inferior surface of the right pulmonary artery. Another longer PTFE graft is anastomosed to the transected inferior vena cava (IVC). A large medial opening in the lower PTFE graft is anastomosed to an atriotomy. These two PTFE tubes are anastomosed with a pericardial patch interposed between them. During the later interventional Fontan procedure, this pericardial patch is perforated using radiofrequency, and a covered stent is positioned entirely within the PTFE tubes, eliminating the window into the common atrium and leaving no intrapulmonary prosthetic material.
EVALUATION: The hemodynamics after the preparatory stage is similar to those following a BCPC, with uninterrupted flow from the IVC to the right atrium. On completion, there is a nonfenestrated Fontan circuit.
CONCLUSION: Our technique of interventional Fontan, anatomically and hemodynamically, mimics a standard ECF procedure.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app