Biological variability of the sweat chloride in diagnostic sweat tests: A retrospective analysis.
BACKGROUND: The sweat test is the current gold standard for the diagnosis of cystic fibrosis (CF). CF is unlikely when sweat chloride (Clsw ) is lower than 30mmol/L, Clsw >60 is suggestive of CF, with intermediate values between 30 and 60mmol/L. To correctly interpret a sweat chloride value, the biological variability of the sweat chloride has to be known.
METHODS: Sweat tests performed in two centers using the classic Gibson and Cooke method were retrospectively reviewed (n=5904). Within test variability of Clsw was measured by comparing results from right and left arm collected on the same day. Between test variability was calculated from subjects with sweat tests performed on more than one occasion.
RESULTS: Within test variability of Clsw calculated in 1022 subjects was low with differences between -3.2 (p5) and +3.6mmol/L (p95). Results from left and right arm were classified differently in only 3 subjects. Between test variability of Clsw in 197 subjects was larger, with differences between -18.2mmol/L (p5) and +14.1mmol/L (p95) between repeat tests. Changes in diagnostic conclusion were seen in 55/197 subjects, the most frequent being changing from indeterminate to 'CF unlikely' range (48/102).
CONCLUSION: Variability of sweat chloride is substantial, with frequent changes in diagnostic conclusion, especially in the intermediate range.
METHODS: Sweat tests performed in two centers using the classic Gibson and Cooke method were retrospectively reviewed (n=5904). Within test variability of Clsw was measured by comparing results from right and left arm collected on the same day. Between test variability was calculated from subjects with sweat tests performed on more than one occasion.
RESULTS: Within test variability of Clsw calculated in 1022 subjects was low with differences between -3.2 (p5) and +3.6mmol/L (p95). Results from left and right arm were classified differently in only 3 subjects. Between test variability of Clsw in 197 subjects was larger, with differences between -18.2mmol/L (p5) and +14.1mmol/L (p95) between repeat tests. Changes in diagnostic conclusion were seen in 55/197 subjects, the most frequent being changing from indeterminate to 'CF unlikely' range (48/102).
CONCLUSION: Variability of sweat chloride is substantial, with frequent changes in diagnostic conclusion, especially in the intermediate range.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app