We have located links that may give you full text access.
Diagnostic Yield and Complications of EBUS-TBNA Performed Under Bronchoscopist-directed Conscious Sedation: Single Center Experience of 1004 Subjects.
Journal of Bronchology & Interventional Pulmonology 2017 January
BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) can be performed under either conscious sedation or general anesthesia. Herein, we describe the diagnostic yield and complications of EBUS-TBNA performed under bronchoscopist-directed conscious sedation.
METHODS: This is a retrospective analysis of data collected in the bronchoscopy suite of this center on EBUS-TBNA or endoscopic ultrasound with a bronchoscope-guided fine needle aspiration (EUS-B-FNA) procedures performed between July 2011 and January 2016. All procedures were performed under bronchoscopist-directed conscious sedation with midazolam and pentazocine. The diagnostic yield, sample adequacy rate, complications, and doses of sedative agents are presented.
RESULTS: Of the total 1005 EBUS-TBNA/EUS-B-FNA procedures performed during the study period, 1004 were performed under conscious sedation in spontaneously breathing subjects [mean (SD) age, 45.9 (15.8) years; 378 (37.6%) women]. The mean (SD) doses of midazolam and pentazocine used were 2.53 (1.8) mg and 30.9 (6.9) mg, respectively. The diagnostic yield of the procedure (972 subjects) was 61.2%. Complications related to EBUS were observed in 60 (5.9%) subjects. Majority of them were minor and self-limiting; major complications occurred in 11 (1.1%) subjects and included respiratory failure requiring assisted ventilation (n=6), arrhythmia (n=3), and hypotension (n=2). Escalation of the level of care was needed in only 8 (0.8%) subjects.
CONCLUSION: EBUS-TBNA/EUS-B-FNA performed under bronchoscopist-guided conscious sedation was found to be safe and is associated with a reasonable diagnostic yield.
METHODS: This is a retrospective analysis of data collected in the bronchoscopy suite of this center on EBUS-TBNA or endoscopic ultrasound with a bronchoscope-guided fine needle aspiration (EUS-B-FNA) procedures performed between July 2011 and January 2016. All procedures were performed under bronchoscopist-directed conscious sedation with midazolam and pentazocine. The diagnostic yield, sample adequacy rate, complications, and doses of sedative agents are presented.
RESULTS: Of the total 1005 EBUS-TBNA/EUS-B-FNA procedures performed during the study period, 1004 were performed under conscious sedation in spontaneously breathing subjects [mean (SD) age, 45.9 (15.8) years; 378 (37.6%) women]. The mean (SD) doses of midazolam and pentazocine used were 2.53 (1.8) mg and 30.9 (6.9) mg, respectively. The diagnostic yield of the procedure (972 subjects) was 61.2%. Complications related to EBUS were observed in 60 (5.9%) subjects. Majority of them were minor and self-limiting; major complications occurred in 11 (1.1%) subjects and included respiratory failure requiring assisted ventilation (n=6), arrhythmia (n=3), and hypotension (n=2). Escalation of the level of care was needed in only 8 (0.8%) subjects.
CONCLUSION: EBUS-TBNA/EUS-B-FNA performed under bronchoscopist-guided conscious sedation was found to be safe and is associated with a reasonable diagnostic yield.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app