Incidence, predictors and outcomes of hematoma after ICD implantation: An analysis of a nationwide database of 85,276 patients.
Indian Pacing and Electrophysiology Journal 2016 September
BACKGROUND: Pocket hematoma is one of the most common complications following cardiac device implantation. This study examined the impact of this complication on in-hospital outcomes following Implantable Cardioverter Defibrillator (ICD) implantation.
METHODS: Data from Nationwide Inpatient Sample (NIS) 2010 was queried to identify all primary implantations of ICDs and Cardiac Resynchronization Therapy Defibrillators (CRT-D) during the year 2010 using ICD-9 codes. We then identified the patients who experienced a procedure related hematoma during the hospital stay. We compared the outcomes of the patients with and without a hematoma complication. All analyses were performed using SPSS 20 complex samples using appropriate weights to adjust for the complex sampling design of the national database.
RESULTS: Out of a total of 85,276 primary ICD implantations in the year 2010, 2233 (2.6% of the implantations) were complicated by a hematoma. Increased age (p < 0.001), and comorbidities such as congestive heart failure (odds ratio (OR) - 1.86, p < 0.001), coagulopathy (OR - 2.3, p < 0.001) and renal failure (OR - 1.52, p < 0.001) were associated with an increased risk of pocket hematoma formation. Patients who developed a hematoma had a longer hospitalization (9.1 days versus 5.5 days, p < 0.001) and higher in-hospital costs ($56,545 versus $47,015, p < 0.001) compared to patients who did not have a hematoma. Overall mortality associated with ICD implantation was low (0.6%), and hematoma formation did not adversely affect mortality (0.6% versus 0.4%, p = 0.63).
CONCLUSION: Hematoma occurs infrequently after ICD implantation, however, it adversely impacts the cost of procedure and length of stay.
METHODS: Data from Nationwide Inpatient Sample (NIS) 2010 was queried to identify all primary implantations of ICDs and Cardiac Resynchronization Therapy Defibrillators (CRT-D) during the year 2010 using ICD-9 codes. We then identified the patients who experienced a procedure related hematoma during the hospital stay. We compared the outcomes of the patients with and without a hematoma complication. All analyses were performed using SPSS 20 complex samples using appropriate weights to adjust for the complex sampling design of the national database.
RESULTS: Out of a total of 85,276 primary ICD implantations in the year 2010, 2233 (2.6% of the implantations) were complicated by a hematoma. Increased age (p < 0.001), and comorbidities such as congestive heart failure (odds ratio (OR) - 1.86, p < 0.001), coagulopathy (OR - 2.3, p < 0.001) and renal failure (OR - 1.52, p < 0.001) were associated with an increased risk of pocket hematoma formation. Patients who developed a hematoma had a longer hospitalization (9.1 days versus 5.5 days, p < 0.001) and higher in-hospital costs ($56,545 versus $47,015, p < 0.001) compared to patients who did not have a hematoma. Overall mortality associated with ICD implantation was low (0.6%), and hematoma formation did not adversely affect mortality (0.6% versus 0.4%, p = 0.63).
CONCLUSION: Hematoma occurs infrequently after ICD implantation, however, it adversely impacts the cost of procedure and length of stay.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app