We have located links that may give you full text access.
Journal Article
Research Support, N.I.H., Extramural
Indoor Spatial Updating With Impaired Vision.
Investigative Ophthalmology & Visual Science 2016 December 2
Purpose: Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions.
Methods: Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation.
Results: The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions.
Conclusions: People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient.
Methods: Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation.
Results: The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions.
Conclusions: People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app