Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer.
Physical Therapy in Sport 2017 March
OBJECTIVES: The present study aimed to assess the between day reliability of isokinetic and isometric peak torque (PT) during trunk measurement on an isokinetic device (IsoMed 2000).
DESIGN: Test-retest-protocol on five separate days.
PARTICIPANTS: Fifteen healthy sport students (8 female and 7 male) aged 21 to 26.
MAIN OUTCOME MEASURES: PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks.
RESULTS: For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85-0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% < CoV < 9.4%; 0.15 < SEM < 0.23) and isokinetic mode (60°/s: 3.7% < CoV < 8.6%; 0.08 < SEM < 0.24; 150°/s: 6.9% < CoV < 12.4%; 0.10 < SEM < 0.31). In contrast, reliability between familiarization day and day 1 was lower (6.6% < CoV < 26.2%; 0.10 < SEM < 0.65).
CONCLUSIONS: Trunk strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied.
DESIGN: Test-retest-protocol on five separate days.
PARTICIPANTS: Fifteen healthy sport students (8 female and 7 male) aged 21 to 26.
MAIN OUTCOME MEASURES: PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks.
RESULTS: For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85-0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% < CoV < 9.4%; 0.15 < SEM < 0.23) and isokinetic mode (60°/s: 3.7% < CoV < 8.6%; 0.08 < SEM < 0.24; 150°/s: 6.9% < CoV < 12.4%; 0.10 < SEM < 0.31). In contrast, reliability between familiarization day and day 1 was lower (6.6% < CoV < 26.2%; 0.10 < SEM < 0.65).
CONCLUSIONS: Trunk strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app