Clinical audit of posterior three-unit fixed-movable resin-bonded fixed partial dentures - A retrospective, preliminary clinical investigation.

Journal of Dentistry 2017 Februrary
BACKGROUND: Two-unit cantilevered resin-bonded fixed partial dentures (RBFPDs) have higher retention rates over longer span fixed-fixed RBFPDs. It has been hypothesized that interabutment stresses associated with fixed-fixed designs cause prosthesis debonds therefore for the replacement of molar-sized and longer spans, non-rigid connectors have been used to allow independent movement between two abutment teeth.

OBJECTIVES: This preliminary study evaluates the clinical longevity and subjects' satisfaction of three-unit fixed-movable (FM3) RBFPDs provided at a dental teaching hospital.

MATERIALS AND METHODS: Subjects who had received FM3 RBFPD(s) in the posterior region were clinically reviewed for complications. History of any debonds and subjects' satisfaction to the prosthesis was recorded. Time-to-debond (retention rate) and time-to-loss (survival rate) of these prostheses were presented in life tables.

RESULTS: Ninety-eight prostheses in 84 subjects were examined. Their mean service life was 31.8 months (SD 11.5, range 3-67 months). Twenty-two prostheses had a history of debond, resulting in a retention proportion of 77.6%; seventeen of these were rebonded and still present at the time of review. One prosthesis was lost after extraction of a periodontally-involved abutment tooth, giving a survival proportion of 93.9%. High subject satisfaction and no adverse outcome were reported.

CONCLUSION: Three-unit fixed-movable RBFPDs have a shorter success than two-unit cantilevered RBFPDs. However, non-rigid connectors allow the possibility of rebonding giving satisfactory short-term survival rate. Further research is needed to investigate their long-term efficacy.

CLINICAL SIGNIFICANCE: Three-unit fixed-movable RBFPDs incorporating non-rigid connectors may be a feasible option for replacement of molar-size pontic in the posterior region.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app