Is It "In" or "Out"? The Optimal Fluoroscopic Views for Intraoperative Determination of Proper Lateral Mass Screw Placement.

Spine 2017 July 16
STUDY DESIGN: Cadaveric.

OBJECTIVE: Determine optimal fluoroscopic views for detecting cervical lateral mass screw (LMS) violations.

SUMMARY OF BACKGROUND DATA: Single plane intraoperative x-rays are commonly used but frequently inadequate due to its complex trajectory. Fluoroscopy can be taken in multiple planes, but the ideal fluoroscopic view to assess malposition is not known: depending on the view, any given screw may look "in" or "out."

METHODS: C3-6 LMS were inserted in three cadavers. To evaluate neuroforaminal violation, LMS were inserted into the foramen with the tip penetrating the anterior cortex by 0, 2, and 4 mm. To assess facet joint violation, LMS were inserted toward the subjacent facet joint with the tip penetrating the anterior cortex by 0 and 2 mm. Fluoroscopic views were taken 0°, 10°, 20°, 30°, and 40° to the lateral plane. Views were independently evaluated by three blinded spine surgeons.

RESULTS: Twenty-degree oblique view correctly identified a 2 mm penetration into the neuroforamen in 79%, and a 4 mm penetration in 86%, for a sensitivity of 83% and specificity of 90%. Thirty-degree view had lower sensitivity (76%) but slightly higher specificity (93%). Twenty-degree and 30° views were significantly more sensitive than the other views. Zero-degree view correctly identified a 2 mm penetration into the facet joint in 93%, for a sensitivity of 93% and specificity of 92%. Ten-degree view had lower sensitivity (72%) but higher specificity (100%). The 0° view was significantly more sensitive than the other views.

CONCLUSION: Twenty-degree and 30° oblique views significantly provided the most sensitive assessment of LMS potentially violating the neuroforamen, whereas the 0° neutral lateral view significantly provided the most sensitive assessment of facet violations. The specificities were also high (in the 90% range) for these views. We recommend the use of these views intraoperatively when assessing proper placement of LMS fluoroscopically.

LEVEL OF EVIDENCE: N/A.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app