We have located links that may give you full text access.
CASE REPORTS
JOURNAL ARTICLE
Incomplete Expansion of Chimney Stent Graft during Chimney-Thoracic Endovascular Aneurysm Repair.
Annals of Vascular Surgery 2017 Februrary
BACKGROUND: To report a technical complication during a chimney-thoracic endovascular aneurysm repair (Ch-TEVAR) procedure.
METHODS: A 77-year-old female patient underwent Ch-TEVAR for a symptomatic thoracic aortic aneurysm with a short and angulated proximal neck. Deployment of the aortic stent graft over the left subclavian artery (LSA) was followed by placement of a balloon-expandable covered stent as a chimney for the LSA.
RESULTS: Chimney deployment failed due to balloon perforation. Additional attempts with several balloons all failed, albeit gaining some additional expansion of the chimney stent graft. The technical complication was solved by deploying a self-expanding bare stent inside the chimney stent. This enabled additional ballooning and further expansion of the chimney stent graft leading to an acceptable end result.
CONCLUSIONS: Ch-TEVAR with a balloon-expandable chimney stent graft can be complicated by incomplete chimney deployment due to balloon perforation. Relining of the chimney stent graft with a self-expanding stent improved the deployment with acceptable patency.
METHODS: A 77-year-old female patient underwent Ch-TEVAR for a symptomatic thoracic aortic aneurysm with a short and angulated proximal neck. Deployment of the aortic stent graft over the left subclavian artery (LSA) was followed by placement of a balloon-expandable covered stent as a chimney for the LSA.
RESULTS: Chimney deployment failed due to balloon perforation. Additional attempts with several balloons all failed, albeit gaining some additional expansion of the chimney stent graft. The technical complication was solved by deploying a self-expanding bare stent inside the chimney stent. This enabled additional ballooning and further expansion of the chimney stent graft leading to an acceptable end result.
CONCLUSIONS: Ch-TEVAR with a balloon-expandable chimney stent graft can be complicated by incomplete chimney deployment due to balloon perforation. Relining of the chimney stent graft with a self-expanding stent improved the deployment with acceptable patency.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app