Does standing or sitting position of the anesthesiologist in the operating theatre influence sevoflurane exposure during craniotomies?
BMC Anesthesiology 2016 December 2
BACKGROUND: Exposure of the OR staff to inhalational anesthetics has been proven by numerous investigators, but its potential adverse effect under the present technical circumstances is a debated issue. The aim of the present work was to test whether using a laminar flow air conditioning system exposure of the team to anesthetic gases is different if the anesthetist works in the sitting as compared to the standing position.
METHODS: Sample collectors were placed at the side of the patient and were fixed at two different heights: at 100 cm (modelling sitting position) and 175 cm (modelling standing position), whereas the third collector was placed at the independent corner of the OR. Collected amount of sevoflurane was determined by an independent chemist using gas chromatography.
RESULTS: At the height of the sitting position the captured amount of sevoflurane was somewhat higher (median and IQR: 0.55; 0.29-1.73 ppm) than that at the height of standing (0.37; 0.15-0.79 ppm), but this difference did not reach the level of statistical significance. A significantly lower sevoflurane concentration was measured at the indifferent corner of the OR (0.14; 0.058-0.36 ppm, p < 0.001).
CONCLUSIONS: Open isolation along with the air flow due to the laminar system does not result in higher anesthetic exposure for the sitting anesthetist positioned to the side of the patient. Evaporated amount of sevoflurane is below the accepted threshold limits in both positions.
METHODS: Sample collectors were placed at the side of the patient and were fixed at two different heights: at 100 cm (modelling sitting position) and 175 cm (modelling standing position), whereas the third collector was placed at the independent corner of the OR. Collected amount of sevoflurane was determined by an independent chemist using gas chromatography.
RESULTS: At the height of the sitting position the captured amount of sevoflurane was somewhat higher (median and IQR: 0.55; 0.29-1.73 ppm) than that at the height of standing (0.37; 0.15-0.79 ppm), but this difference did not reach the level of statistical significance. A significantly lower sevoflurane concentration was measured at the indifferent corner of the OR (0.14; 0.058-0.36 ppm, p < 0.001).
CONCLUSIONS: Open isolation along with the air flow due to the laminar system does not result in higher anesthetic exposure for the sitting anesthetist positioned to the side of the patient. Evaporated amount of sevoflurane is below the accepted threshold limits in both positions.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app