We have located links that may give you full text access.
Carotid Arterial Flow in Pseudoexfoliation Glaucoma and its Role in Diagnosing the Disease.
Journal of Glaucoma 2016 December
OBJECTIVE OF THE STUDY: The objective of the study was to investigate the change in carotid arterial flow in pseudoexfoliation glaucoma (XFG) for determining its diagnostic value.
MATERIALS AND METHODS: Patients with XFG (N=30) and control subjects (N=22) were recruited. Common carotid artery (CCA) and internal carotid artery of each participant were examined using color Doppler and B-mode ultrasonography. Resistivity index (RI), as a flow parameter of interest, was measured and statistically compared between the 2 groups. Receiver operating characteristic was also produced to assess its diagnostic value.
RESULTS: The measured RI values from the controls were within the expected range. Among CCA and internal carotid artery, only RI of CCA exhibited statistically significant changes in XFG (0.75±0.04 vs. 0.70±0.03 cm/s). Threshold value of RI=0.72 yielded 90% sensitivity and 73% specificity in distinguishing the cases of XFG from the controls.
CONCLUSIONS: Flow dynamics of carotid arterial system exhibits different characteristics in individuals with XFG than controls. Such differences may serve as a basis for developing potentially new diagnostic biomarkers of XFG. Further studies are justified for examining the carotid flow in pseudoexfoliation syndrome and compare it against XFG for determining its power in differential diagnosis.
MATERIALS AND METHODS: Patients with XFG (N=30) and control subjects (N=22) were recruited. Common carotid artery (CCA) and internal carotid artery of each participant were examined using color Doppler and B-mode ultrasonography. Resistivity index (RI), as a flow parameter of interest, was measured and statistically compared between the 2 groups. Receiver operating characteristic was also produced to assess its diagnostic value.
RESULTS: The measured RI values from the controls were within the expected range. Among CCA and internal carotid artery, only RI of CCA exhibited statistically significant changes in XFG (0.75±0.04 vs. 0.70±0.03 cm/s). Threshold value of RI=0.72 yielded 90% sensitivity and 73% specificity in distinguishing the cases of XFG from the controls.
CONCLUSIONS: Flow dynamics of carotid arterial system exhibits different characteristics in individuals with XFG than controls. Such differences may serve as a basis for developing potentially new diagnostic biomarkers of XFG. Further studies are justified for examining the carotid flow in pseudoexfoliation syndrome and compare it against XFG for determining its power in differential diagnosis.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app