We have located links that may give you full text access.
Journal Article
Validation Studies
Capillary electrophoresis with online stacking in combination with AgNPs@MCM-41 reinforced hollow fiber solid-liquid phase microextraction for quantitative analysis of Capecitabine and its main metabolite 5-Fluorouracil in plasma samples isolated from cancer patients.
Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences 2017 January 2
The purpose of this study is the development and validation of a simple, novel, selective and fast off-line microextraction technique combining capillary electrophoresis with in-column field-amplified sample injection (FASI) for the simultaneous determination of capecitabine (CAP) and its active metabolite, 5-Fluorouracil (5-FU), in human plasma. At the moment, there is a lack of using cost-effective CE tool combined with novel miniaturized sample clean-up techniques for analysis of these important anti-cancer agents in plasma samples. This paper intends to fill this gap and describe a simple off-line sample pretreatment by means of AgNPs@MCM-41 reinforced hollow fiber Solid/Liquid phase microextraction (AgNPs@MCM41-HF-SLPME) with subsequent quantitation by FASI-CE. The separation of analytes was performed using a BGE containing 60mM phosphate-Tris buffer (pH 7) with 10% methanol as an organic modifier. Before sample loading, a short water plug (50mbar, 3s) was injected to permit FASI for stacking. Various parameters affecting the off-line microextraction efficiency as well as FASI were optimized. Migration time was found to be 6.6 (±0.1)min for 5-FU and 7.4 (±0.2)min for CAP. The linearity, precision, accuracy, recovery, selectivity, specificity, stability as well as the robustness of the method was evaluated from spiked plasma samples during the course of validation. The results revealed that the presented technique demonstrates acceptable accuracy and precision, miniaturized sample preparation and a reduced need for complicated equipment along with an acceptable analysis time. The validated method was successfully applied to determine CAP and 5-FU in patient's plasma samples.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app