Accuracy of impression scanning compared with stone casts of implant impressions.
Journal of Prosthetic Dentistry 2017 April
STATEMENT OF PROBLEM: Accurate virtual implant models are a necessity for the fabrication of precisely fitting superstructures.
PURPOSE: The purpose of this in vitro study was to evaluate different methods with which to build an accurate virtual model of a 3-dimensional implant in the oral cavity; this model would then be used for iterative computer-aided design and computer-aided manufacturing (CAD-CAM) procedures.
MATERIAL AND METHODS: A titanium master model with 3 rigidly connected implants was manufactured and digitized with a noncontact industrial scanner to obtain a virtual master model. Impressions of the master model with the implant position locators (IPL) were made using vinyl siloxanether material. The impressions were scanned (Impression scanning technique group). For the transfer technique and pick-up technique groups (each group n=20), implant analogs were inserted into the impression copings, impressions were made using polyether, and casts were poured in Type 4 gypsum. The IPLs were screwed into the analogs and scanned. To compare the virtual master model with each virtual test model, a CAD interactive software, ATOS professional, was applied. The Kruskal-Wallis test was subsequently used to determine the overall difference between groups, with the Mann-Whitney U test used for pairwise comparisons. Through Bonferroni correction, the α-level was set to .017.
RESULTS: The outcome revealed a significant difference among the 3 groups (P<.01) in terms of accuracy. With regard to total deviation, for all axes, the transfer technique generated the greatest divergence, 0.078 mm (±0.022), compared with the master model. Deviation with the pick-up technique was 0.041 mm (±0.009), with impression scanning generating the most accurate models with a deviation of 0.022 mm (±0.007).
CONCLUSIONS: The impression scanning method improved the precision of CAD-CAM-fabricated superstructures.
PURPOSE: The purpose of this in vitro study was to evaluate different methods with which to build an accurate virtual model of a 3-dimensional implant in the oral cavity; this model would then be used for iterative computer-aided design and computer-aided manufacturing (CAD-CAM) procedures.
MATERIAL AND METHODS: A titanium master model with 3 rigidly connected implants was manufactured and digitized with a noncontact industrial scanner to obtain a virtual master model. Impressions of the master model with the implant position locators (IPL) were made using vinyl siloxanether material. The impressions were scanned (Impression scanning technique group). For the transfer technique and pick-up technique groups (each group n=20), implant analogs were inserted into the impression copings, impressions were made using polyether, and casts were poured in Type 4 gypsum. The IPLs were screwed into the analogs and scanned. To compare the virtual master model with each virtual test model, a CAD interactive software, ATOS professional, was applied. The Kruskal-Wallis test was subsequently used to determine the overall difference between groups, with the Mann-Whitney U test used for pairwise comparisons. Through Bonferroni correction, the α-level was set to .017.
RESULTS: The outcome revealed a significant difference among the 3 groups (P<.01) in terms of accuracy. With regard to total deviation, for all axes, the transfer technique generated the greatest divergence, 0.078 mm (±0.022), compared with the master model. Deviation with the pick-up technique was 0.041 mm (±0.009), with impression scanning generating the most accurate models with a deviation of 0.022 mm (±0.007).
CONCLUSIONS: The impression scanning method improved the precision of CAD-CAM-fabricated superstructures.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app