Add like
Add dislike
Add to saved papers

Practicalities of mapping PM 10 and PM 2.5 concentrations on city-wide scales using a portable particulate monitor.

Fine particulate matter is considered to be the most significant ambient air pollutant in terms of potential health impacts. Therefore, it is important that regulators are able to accurately assess the exposure of populations to PM10 and PM2.5 across municipal areas. We report on the practicalities of using a laser light scattering portable particulate monitor (Turnkey Instruments DustMate), in combination with a GPS, to map PM10 and PM2.5 concentrations on city-wide scales in Newcastle upon Tyne/Gateshead (UK), during a series of walking surveys. A heated inlet is necessary to remove moisture droplets from the sampled air prior to analysis by the instrument, though this also results in the loss of volatile particulate components, particularly from the PM2.5 fraction. A co-location calibration study was carried out with a reference urban background Tapered Element Oscillating Micro-Balance/Filter Dynamics Measuring System (TEOM-FDMS) system in Newcastle that is part of the UK's Automatic Urban and Rural Network (AURN) of air quality monitoring stations. For PM10 , orthogonal regression of the DustMate against TEOM-FDMS data gave a slope and intercept of 1.02 ± 0.06 and -3.7 ± 1.2, respectively ( R 2  = 0.73), whereas for PM2.5 , the respective values were 0.78 ± 0.06 and -0.63 ± 0.55 ( R 2  = 0.79). These parameters are comparable to literature calibration studies using this technology. There was good agreement between simultaneous samples taken using two DustMate instruments: for PM10 , a slope and intercept of 1.05 ± 0.03 and 0.36 ± 0.5, respectively ( R 2  = 0.73), were obtained, whereas for the PM2.5 , the respective values were 0.79 ± 0.01 and 0.19 ± 0.06 ( R 2  = 0.86). Correction factors based on the slope and intercepts obtained from the calibration exercise were applied to raw data collected from the DustMate. An annually-normalised correction procedure was then used to account for different background particulate concentrations on different sampling days. These corrected PM10 and PM2.5 concentrations and corresponding GPS coordinates were displayed on a base map using Google Fusion Tables and Google Earth Professional. Almost all areas surveyed in Newcastle/Gateshead were well below the EU Air Quality Standards for PM10 and PM2.5 .

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app