Understanding the impact of pelvic organ motion on dose delivered to target volumes during IMRT for cervical cancer.

BACKGROUND: Advanced radiotherapy techniques reduce normal tissue dose by conforming closely to target volumes. In cervical cancer radiotherapy, organ filling affects clinical target volume (CTV; cervix, uterus) position. This study estimates the dosimetric effect of this primary CTV position variation during chemoradiation.

METHODS/MATERIALS: Twice weekly cone-beam computed tomography (CBCT) images of ten patients undergoing cervical chemoradiation were retrospectively analysed. Primary CTV, bladder and rectum were delineated. RapidArc plans were created using 10-15mm CTV-PTV margins and dose delivered to CTV based on each CBCT position was calculated using a novel vector approach. Dose delivered along the central uterine, mid-uterus and cervix vectors were analysed as well as dose delivered to points at uterine tip, anterior mid-uterus and anterior cervix. Additional RapidArc plans were created for large planning bladder volume cases using the CTV acquired with bladder volume at 150-300cc.

RESULTS: 105 scans for 10 patients were analysed. Vector analysis revealed CTV underdosing in certain cases. Below 95% average vector coverage was found for all three vectors in 2 cases and one vector in 1 case. Volumetric analysis revealed D99<95% in 48% of fractions. Patients with large planning bladder volumes (>300cc) demonstrated the largest variation. Replanning improved this coverage. The anterior mid-uterus point was least well-covered; median 98.7% dose, reducing to 91.4% in cases with large planning bladder volumes. Again, replanning significantly improved this. D99>95% was maintained in 93% of fractions when bladder volume was 50cc below to 150cc above planning volume compared to 24% of fractions if bladder volume was outside this range. Similarly, D95>95% was 100% versus 84%.

CONCLUSION: Organ position variation detrimentally affected dose delivered to CTV including cervix. Large planning bladder volumes (>300cc) led to more variation. We recommend bladder volumes of 150-300cc at planning and a range of 50cc below to 150cc above planning for treatment.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app