Add like
Add dislike
Add to saved papers

The Genovese grading scale is not reliable for MR assessment of collagen meniscus implants.

Knee 2017 January
BACKGROUND: The purpose of the study was to evaluate the intra- and inter-observer reliabilities of the Genovese grading on MRI in patients after collagen meniscus substitution.

METHODS: 84 MRI images of 74 consecutive patients who underwent partial meniscus substitution using collagen meniscus implant (CMI) were assessed. MRIs were evaluated using the Genovese grading system. Furthermore, meniscal extrusion was assessed. Two observers performed the grading twice, blinded to each other and to the previous results, with a six weeks interval. The inter- and intra-observer reliabilities were assessed using kappa and weighted kappa values.

RESULTS: The criterion "morphology/size" showed a weighted kappa value inter-observer reliability of 0.069 (rater 1)/0.352 (rater 2) and intra-observer reliability of 0.170 (1st rating)/0.582 (2nd rating). The criterion "signal intensity" showed a weighted kappa value inter-observer reliability of 0.175/0.284 and intra-observer reliability of 0.294/0.458. The criterion "cartilage lesions" showed a kappa value inter-observer reliability of 0.091/0.525 and intra-observer reliability of 0.409/0.413. The criterion "bone marrow edema" showed a kappa value inter-observer reliability of 0.667/0.808 and intra-observer reliability of 0.702/0.715. The criterion "cartilage lesions" showed a kappa value inter-observer reliability of 0.091/0.525 and intra-observer reliability of 0.409/0.413. Regarding meniscal extrusion kappa values for the inter-observer reliability were 0.625/0.940 and 0.625/0.889 for intra-observer reliability.

CONCLUSIONS: Three of the four Genovese grading items showed only slight to moderate inter- and intra-observer reliabilities in evaluating CMI on MRI. Hence, such grading results need to be considered with all due care. Only the criteria "bone marrow edema" and "meniscal extrusion" showed a good agreement for both inter- and intra-observer reliabilities.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app