JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Add like
Add dislike
Add to saved papers

Intrauterine contraception after medical abortion: factors affecting success of early insertion.

Contraception 2017 March
OBJECTIVE: To assess the success and factors affecting early intrauterine device (IUD) provision after first trimester medical termination of pregnancy (MTOP).

STUDY DESIGN: Subgroup analysis of a randomized contraceptive trial assessing the long-term effects of early provision of intrauterine contraception following abortion. Altogether, 606 women undergoing MTOP were included and followed for 3 months. The intervention group (n=307) was offered an IUD (either the levonorgestrel-releasing intrauterine system or copper-IUD) at a follow-up visit 1-4 weeks after MTOP. The control group (n=299) contacted primary health care for follow-up and contraceptive provision. Adverse events (infections, bleeding, residual tissue and incomplete abortion) were analyzed on intention-to-treat basis and IUD expulsions on per-protocol (PP) basis.

RESULTS: In the intervention group, 234 women (76.2%) received the IUD as scheduled, 46 later (altogether 91.2%). In the control group, the corresponding figures were 8 (2.7%) and 64 [altogether 24.1%, Odds ratio (OR) (95% Confidence interval (CI))=32.7 (20.3-52.6)]. Eighty-five (27.7%) women in the intervention group and 38 (12.7%) in the control group received treatment (administration of antibiotics, misoprostol or surgical evacuation) because of presumed adverse event [2.63 (1.72-4.01)], mainly residual tissue. In the control group, 23 (60.5%) of these occurred during the first 2 weeks. IUD expulsion occurred in 12 (5.4%) of the 222 women in the intervention group (PP basis).

CONCLUSIONS: When provided as part of abortion service, most early insertions following MTOP were performed as planned. The main reason for postponement was overdiagnosis of adverse events suspected at follow-up. The rate of IUD expulsion was similar to that reported previously.

IMPLICATIONS: Early insertion following MTOP is safe, and the rate of IUD expulsion is low. Most adverse events possibly delaying IUD insertion occur early. Based on timing of adverse events in the control group, IUD insertion at approximately 2 weeks after completed MTOP seems optimal.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app