We have located links that may give you full text access.
All that bleeds is not black: susceptibility weighted imaging of intracranial hemorrhage and the effect of T1 signal.
Clinical Imaging 2017 January
PURPOSE: To determine if intracranial hemorrhages (ICH) are always hypointense on Susceptibility weighted imaging (SWI) and to determine the effect of T1-signal intensity on the appearance of ICH in SWI series.
METHODS: SWI and T1-signal intensities of ICH were retrospectively studied in a series of patients. SWI signal intensities were statistically correlated with T1-signal intensities.
RESULTS: In a series of 57 MRI scans from 40 patients, ICH was hypointense in 19, mixed-intensity in 21, and hyperintense in 17. Hyperintensity of ICH on SWI was significantly associated with increased T1 signal (P<.001).
CONCLUSION: ICH can have a varied appearance on SWI.
METHODS: SWI and T1-signal intensities of ICH were retrospectively studied in a series of patients. SWI signal intensities were statistically correlated with T1-signal intensities.
RESULTS: In a series of 57 MRI scans from 40 patients, ICH was hypointense in 19, mixed-intensity in 21, and hyperintense in 17. Hyperintensity of ICH on SWI was significantly associated with increased T1 signal (P<.001).
CONCLUSION: ICH can have a varied appearance on SWI.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app