Pulmonary Arteriovenous Malformations Embolized Using a Micro Vascular Plug System: Technical Note on a Preliminary Experience.
Cardiovascular and Interventional Radiology 2017 Februrary
AIM: To report our preliminary experience using a Micro Vascular Plug (MVP) deployed through a 2.8Fr micro-catheter for the treatment of pulmonary arteriovenous malformations (PAVMs) in a cohort of patients affected by Hereditary Haemorrhagic Telangiectasia (HHT).
MATERIALS AND METHODS: Four consecutive female patients (mean age 38.0 years; range 25-55 years) with PAVMs diagnosed on echocardiogram/bubble test and contrast-enhanced CT (CECT) underwent MVP embolization. One patient was symptomatic with recent transient ischaemic attack. Follow-up was undertaken at 1-month post-procedure with CECT to assess PAVMs permeability and MVP positioning and at 1-, 6-, and 12-month post-procedure, with echocardiography/bubble test and standard neurological history, to confirm absence of right-to-left shunts and recurrent symptoms.
RESULTS: Eight PAVMs were treated in 4 patients over 5 interventional sessions (mean 1.6 PAVMs per session). All PAVMs were simple, with mean feeding artery diameter of 4.25 mm. Eight 6.5 mm MVPs were deployed in total (one per lesion). Technical success was 100%. Mean procedural time and patient dose per session were 70 min (range 40-70 min) and 53418 mGy.cm2 (range 6113-101628 mGy.cm2 ), respectively. No signs of reperfusion neither of MPV migration were noted at 1-month CECT follow-up. At early follow-up (mean 3.75 months; range 1-12 months), clinical success was 100% with no evidence of recurrent right-to-left shunt, and no neurological symptoms. No immediate or late complications were observed.
CONCLUSIONS: MVP embolization of PAVMs appears technically feasible, safe, and effective at early follow-up. Further prospective studies are required to confirm long-term safety and efficacy of this promising technique.
MATERIALS AND METHODS: Four consecutive female patients (mean age 38.0 years; range 25-55 years) with PAVMs diagnosed on echocardiogram/bubble test and contrast-enhanced CT (CECT) underwent MVP embolization. One patient was symptomatic with recent transient ischaemic attack. Follow-up was undertaken at 1-month post-procedure with CECT to assess PAVMs permeability and MVP positioning and at 1-, 6-, and 12-month post-procedure, with echocardiography/bubble test and standard neurological history, to confirm absence of right-to-left shunts and recurrent symptoms.
RESULTS: Eight PAVMs were treated in 4 patients over 5 interventional sessions (mean 1.6 PAVMs per session). All PAVMs were simple, with mean feeding artery diameter of 4.25 mm. Eight 6.5 mm MVPs were deployed in total (one per lesion). Technical success was 100%. Mean procedural time and patient dose per session were 70 min (range 40-70 min) and 53418 mGy.cm2 (range 6113-101628 mGy.cm2 ), respectively. No signs of reperfusion neither of MPV migration were noted at 1-month CECT follow-up. At early follow-up (mean 3.75 months; range 1-12 months), clinical success was 100% with no evidence of recurrent right-to-left shunt, and no neurological symptoms. No immediate or late complications were observed.
CONCLUSIONS: MVP embolization of PAVMs appears technically feasible, safe, and effective at early follow-up. Further prospective studies are required to confirm long-term safety and efficacy of this promising technique.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app