Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient's and Physical Therapist's Perspective.

BACKGROUND: Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient's compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user's perspective.

AIM: To describe the usability from the physical therapists' and a patients' perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery.

METHODS: In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used.

RESULTS: Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability.

CONCLUSION: This study gives insight in the usability of two biofeedback devices from the patient's and physical therapist's perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient's perspective.

IMPLICATION: The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app