COMPARATIVE STUDY
JOURNAL ARTICLE
OBSERVATIONAL STUDY
Add like
Add dislike
Add to saved papers

Ultrasound and histological measurements of dividing membrane thickness in twin gestations.

OBJECTIVE: To determine how prenatal ultrasound measurements of dividing membrane thickness correlate with postnatal histological measurements and chorionicity in twin gestations.

METHODS: This was a prospective, longitudinal cohort study of twin gestations. Dividing membrane thickness was measured by transabdominal ultrasound, with the insonation beam both parallel and perpendicular to the membrane, in the second or third trimester, depending on when care was established. Ultrasound examinations were performed every 4 weeks following initial assessment until delivery. Measurements of membrane thickness from the first ultrasound examination were compared with histological measurements after delivery.

RESULTS: A total of 45 twin pregnancies (32 dichorionic, 13 monochorionic) were included. Mean gestational age at initial ultrasound examination was 24.1 ± 7.3 weeks. Parallel ultrasound measurements of membrane thickness were 1.6 ± 0.8 mm for monochorionic and 2.5 ± 0.9 mm for dichorionic gestations (P = 0.001). Perpendicular ultrasound measurements were 1.6 ± 0.3 mm for monochorionic and 2.2 ± 0.8 mm for dichorionic gestations (P = 0.009). Inter- and intraobserver reliability of ultrasound measurements were 0.847 and 0.950, respectively. Parallel and perpendicular ultrasound measurements correlated better with each other (R = 0.807, P < 0.001) than with histological measurements of membrane thickness (Rparallel  = 0.538, P < 0.001; Rperpendicular  = 0.529, P < 0.001). Receiver-operating characteristics curve analyses to predict histological membrane thickness > 50th percentile resulted in an area under the curve (AUC) of 0.828 for parallel (P < 0.001) and 0.874 for perpendicular (P < 0.001) measurements with a cut-off value of 1.9 mm for both approaches. The AUCs for parallel and perpendicular measurements to predict dichorionicity were 0.892 (P < 0.001) and 0.823 (P < 0.001) with cut-off values of 1.9 and 1.8 mm, respectively.

CONCLUSION: Prenatal ultrasound measurement of twin dividing membrane thickness is positively correlated with postnatal histological measurement. Dichorionicity can be determined by a magnified dividing membrane thickness ≥ 1.9 mm. Measurements with the ultrasound beam parallel to the dividing membrane may be more accurate than perpendicular measurements. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app