Ultrasound and histological measurements of dividing membrane thickness in twin gestations.
Ultrasound in Obstetrics & Gynecology 2017 October
OBJECTIVE: To determine how prenatal ultrasound measurements of dividing membrane thickness correlate with postnatal histological measurements and chorionicity in twin gestations.
METHODS: This was a prospective, longitudinal cohort study of twin gestations. Dividing membrane thickness was measured by transabdominal ultrasound, with the insonation beam both parallel and perpendicular to the membrane, in the second or third trimester, depending on when care was established. Ultrasound examinations were performed every 4 weeks following initial assessment until delivery. Measurements of membrane thickness from the first ultrasound examination were compared with histological measurements after delivery.
RESULTS: A total of 45 twin pregnancies (32 dichorionic, 13 monochorionic) were included. Mean gestational age at initial ultrasound examination was 24.1 ± 7.3 weeks. Parallel ultrasound measurements of membrane thickness were 1.6 ± 0.8 mm for monochorionic and 2.5 ± 0.9 mm for dichorionic gestations (P = 0.001). Perpendicular ultrasound measurements were 1.6 ± 0.3 mm for monochorionic and 2.2 ± 0.8 mm for dichorionic gestations (P = 0.009). Inter- and intraobserver reliability of ultrasound measurements were 0.847 and 0.950, respectively. Parallel and perpendicular ultrasound measurements correlated better with each other (R = 0.807, P < 0.001) than with histological measurements of membrane thickness (Rparallel = 0.538, P < 0.001; Rperpendicular = 0.529, P < 0.001). Receiver-operating characteristics curve analyses to predict histological membrane thickness > 50th percentile resulted in an area under the curve (AUC) of 0.828 for parallel (P < 0.001) and 0.874 for perpendicular (P < 0.001) measurements with a cut-off value of 1.9 mm for both approaches. The AUCs for parallel and perpendicular measurements to predict dichorionicity were 0.892 (P < 0.001) and 0.823 (P < 0.001) with cut-off values of 1.9 and 1.8 mm, respectively.
CONCLUSION: Prenatal ultrasound measurement of twin dividing membrane thickness is positively correlated with postnatal histological measurement. Dichorionicity can be determined by a magnified dividing membrane thickness ≥ 1.9 mm. Measurements with the ultrasound beam parallel to the dividing membrane may be more accurate than perpendicular measurements. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
METHODS: This was a prospective, longitudinal cohort study of twin gestations. Dividing membrane thickness was measured by transabdominal ultrasound, with the insonation beam both parallel and perpendicular to the membrane, in the second or third trimester, depending on when care was established. Ultrasound examinations were performed every 4 weeks following initial assessment until delivery. Measurements of membrane thickness from the first ultrasound examination were compared with histological measurements after delivery.
RESULTS: A total of 45 twin pregnancies (32 dichorionic, 13 monochorionic) were included. Mean gestational age at initial ultrasound examination was 24.1 ± 7.3 weeks. Parallel ultrasound measurements of membrane thickness were 1.6 ± 0.8 mm for monochorionic and 2.5 ± 0.9 mm for dichorionic gestations (P = 0.001). Perpendicular ultrasound measurements were 1.6 ± 0.3 mm for monochorionic and 2.2 ± 0.8 mm for dichorionic gestations (P = 0.009). Inter- and intraobserver reliability of ultrasound measurements were 0.847 and 0.950, respectively. Parallel and perpendicular ultrasound measurements correlated better with each other (R = 0.807, P < 0.001) than with histological measurements of membrane thickness (Rparallel = 0.538, P < 0.001; Rperpendicular = 0.529, P < 0.001). Receiver-operating characteristics curve analyses to predict histological membrane thickness > 50th percentile resulted in an area under the curve (AUC) of 0.828 for parallel (P < 0.001) and 0.874 for perpendicular (P < 0.001) measurements with a cut-off value of 1.9 mm for both approaches. The AUCs for parallel and perpendicular measurements to predict dichorionicity were 0.892 (P < 0.001) and 0.823 (P < 0.001) with cut-off values of 1.9 and 1.8 mm, respectively.
CONCLUSION: Prenatal ultrasound measurement of twin dividing membrane thickness is positively correlated with postnatal histological measurement. Dichorionicity can be determined by a magnified dividing membrane thickness ≥ 1.9 mm. Measurements with the ultrasound beam parallel to the dividing membrane may be more accurate than perpendicular measurements. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app