BACKGROUND: Wearable measurement of center of pressure (COP) coordinates is the key of obtaining the measurement of natural gait. Plantar pressure insole is the right sensing unit for plantar pressure monitoring for long-term outdoor measurements and the control of walking assisting exoskeleton robot. It's necessary to study the configuration of pressure sensing cells.
METHODS: This study explored the sensing cell configuration for the plantar pressure insole. The data of plantar pressure of walking is collected for layout variants. The RMSE of COP coordinates estimations are used as the evaluation criteria.
RESULTS: The RMSE of COP coordinates decreases from 8.00 to 3.20 mm as the amount of pressure sensing cells increases from 2 to 7. The size of pressure sensing cells contribute to reduce the RMSE of COP coordinates and 7 pressure sensing cells, with the size of 2.0-2.5 cm have the satisfying performance. Adding pressure sensing cell in the heel and hallux area increase the accuracy of estimating COP coordinates.
CONCLUSION: Comparison results indicate that the configuration of 7 pressure sensing cells has a satisfying measurement performance.
METHODS: This study explored the sensing cell configuration for the plantar pressure insole. The data of plantar pressure of walking is collected for layout variants. The RMSE of COP coordinates estimations are used as the evaluation criteria.
RESULTS: The RMSE of COP coordinates decreases from 8.00 to 3.20 mm as the amount of pressure sensing cells increases from 2 to 7. The size of pressure sensing cells contribute to reduce the RMSE of COP coordinates and 7 pressure sensing cells, with the size of 2.0-2.5 cm have the satisfying performance. Adding pressure sensing cell in the heel and hallux area increase the accuracy of estimating COP coordinates.
CONCLUSION: Comparison results indicate that the configuration of 7 pressure sensing cells has a satisfying measurement performance.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app