We have located links that may give you full text access.
JOURNAL ARTICLE
VALIDATION STUDY
Objective, computerized video-based rating of blepharospasm severity.
Neurology 2016 November 16
OBJECTIVE: To compare clinical rating scales of blepharospasm severity with involuntary eye closures measured automatically from patient videos with contemporary facial expression software.
METHODS: We evaluated video recordings of a standardized clinical examination from 50 patients with blepharospasm in the Dystonia Coalition's Natural History and Biorepository study. Eye closures were measured on a frame-by-frame basis with software known as the Computer Expression Recognition Toolbox (CERT). The proportion of eye closure time was compared with 3 commonly used clinical rating scales: the Burke-Fahn-Marsden Dystonia Rating Scale, Global Dystonia Rating Scale, and Jankovic Rating Scale.
RESULTS: CERT was reliably able to find the face, and its eye closure measure was correlated with all of the clinical severity ratings (Spearman ρ = 0.56, 0.52, and 0.56 for the Burke-Fahn-Marsden Dystonia Rating Scale, Global Dystonia Rating Scale, and Jankovic Rating Scale, respectively, all p < 0.0001).
CONCLUSIONS: The results demonstrate that CERT has convergent validity with conventional clinical rating scales and can be used with video recordings to measure blepharospasm symptom severity automatically and objectively. Unlike EMG and kinematics, CERT requires only conventional video recordings and can therefore be more easily adopted for use in the clinic.
METHODS: We evaluated video recordings of a standardized clinical examination from 50 patients with blepharospasm in the Dystonia Coalition's Natural History and Biorepository study. Eye closures were measured on a frame-by-frame basis with software known as the Computer Expression Recognition Toolbox (CERT). The proportion of eye closure time was compared with 3 commonly used clinical rating scales: the Burke-Fahn-Marsden Dystonia Rating Scale, Global Dystonia Rating Scale, and Jankovic Rating Scale.
RESULTS: CERT was reliably able to find the face, and its eye closure measure was correlated with all of the clinical severity ratings (Spearman ρ = 0.56, 0.52, and 0.56 for the Burke-Fahn-Marsden Dystonia Rating Scale, Global Dystonia Rating Scale, and Jankovic Rating Scale, respectively, all p < 0.0001).
CONCLUSIONS: The results demonstrate that CERT has convergent validity with conventional clinical rating scales and can be used with video recordings to measure blepharospasm symptom severity automatically and objectively. Unlike EMG and kinematics, CERT requires only conventional video recordings and can therefore be more easily adopted for use in the clinic.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app